Skip to main content
U.S. Department of Energy
Office of Scientific and Technical Information

POWER LEVEL AND ENRICHMENT LIMITATIONS OF THE HANFORD TEST PILE

Technical Report ·
OSTI ID:4028219
Flux levels were determined for the Hanford Test Pile by measuring the current from several ion chambers with a galvanometer. From these measurements, calculations were made of total power level. Results indicated that maximum power levels of the order of 10,000 watts and maximum lrradiations of 10,000 watt- hours are permissible. Enrichment of the Test Pile with up to 100 inhours of calculated strength of enrichment was found to be permissible using certain procedures. The radiation levels to be expected at various points in the building are listed. (M.C.G.)
Research Organization:
General Electric Co. Hanford Atomic Products Operation, Richland, Wash.
NSA Number:
NSA-15-016641
OSTI ID:
4028219
Report Number(s):
HW-53496
Country of Publication:
Country unknown/Code not available
Language:
English

Similar Records

Future power levels of Hanford Piles
Technical Report · Tue May 31 00:00:00 EDT 1955 · OSTI ID:10104673

Relocation of radial enrichment at the K reactors to decrease enrichment inventory
Technical Report · Tue Mar 27 23:00:00 EST 1962 · OSTI ID:10149995

Hanford test pile