Preliminary evaluation of a high-g shock miniature AT strip resonator
Technical Report
·
OSTI ID:10141270
An ever increasing demand for highly rugged, miniature AT strip resonators prompted the development of a resonator package for use in high-g shock applications. This package, designed and developed by Statek Corporation, is based on the package configuration currently being used by Statek for commercial devices. This report describes the design intent, component characteristics, and evaluation test results for this device.