Hanford double shell tank corrosion monitoring instrument trees
Conference
·
OSTI ID:10116761
High-level nuclear wastes at the Hanford site are stored underground in carbon steel double-shell and single-shell tanks - (DSTs and SSTS). Westinghouse Hanford Company is considering installation of a prototype corrosion monitoring instrument tree in at least one DST in the summer of 1995. The instrument tree will have the ability to detect and discriminate between uniform corrosion, stress corrosion cracking (SCC), and pitting. Additional instrument trees will follow in later years. Proof-of-technology testing is currently underway for the use of commercially available electric field pattern (EFP) analysis and electrochemical noise (EN) corrosion monitoring equipment. Creative use and combinations of other existing technologies is also being considered. Successful demonstration of these technologies will be followed by the development of a Hanford specific instrument tree. The first instrument tree will incorporate one of these technologies. Subsequent trees may include both technologies, as well as a more standard assembly of corrosion coupons. Successful development of these trees will allow their application to single shell tanks and the transfer of technology to other U.S. Department of Energy (DOE) sites.
- Research Organization:
- Westinghouse Hanford Co., Richland, WA (United States)
- Sponsoring Organization:
- USDOE, Washington, DC (United States)
- DOE Contract Number:
- AC06-87RL10930
- OSTI ID:
- 10116761
- Report Number(s):
- WHC-SA--2544; CONF-950304--11; ON: DE95005161
- Country of Publication:
- United States
- Language:
- English
Similar Records
Hanford double shell tank corrosion monitoring instrument tree prototype
Design of second generation Hanford tank corrosion monitoring system
Corrosion monitoring of high-level waste tanks
Conference
·
Tue Oct 31 23:00:00 EST 1995
·
OSTI ID:206477
Design of second generation Hanford tank corrosion monitoring system
Technical Report
·
Wed Apr 01 23:00:00 EST 1998
·
OSTI ID:353279
Corrosion monitoring of high-level waste tanks
Conference
·
Sun Oct 31 23:00:00 EST 1993
·
OSTI ID:10112064