Title: Design studies for ITER x-ray diagnostics

Technical Report ·
DOI:https://doi.org/10.2172/10110841· OSTI ID:10110841

Concepts for adapting conventional tokamak x-ray diagnostics to the harsh radiation environment of ITER include use of grazing-incidence (GI) x-ray mirrors or man-made Bragg multilayer (ML) elements to remove the x-ray beam from the neutron beam, or use of bundles of glass-capillary x-ray ``light pipes`` embedded in radiation shields to reduce the neutron/gamma-ray fluxes onto the detectors while maintaining usable x-ray throughput. The x-ray optical element with the broadest bandwidth and highest throughput, the GI mirror, can provide adequate lateral deflection (10 cm for a deflected-path length of 8 m) at x-ray energies up to 12, 22, or 30 keV for one, two, or three deflections, respectively. This element can be used with the broad band, high intensity x-ray imaging system (XIS), the pulseheight analysis (PHA) survey spectrometer, or the high resolution Johann x-ray crystal spectrometer (XCS), which is used for ion-temperature measurement. The ML mirrors can isolate the detector from the neutron beam with a single deflection for energies up to 50 keV, but have much narrower bandwidth and lower x-ray power throughput than do the GI mirrors; they are unsuitable for use with the XIS or PHA, but they could be used with the XCS; in particular, these deflectors could be used between ITER and the biological shield to avoid direct plasma neutron streaming through the biological shield. Graded-d ML mirrors have good reflectivity from 20 to 70 keV, but still at grazing angles (<3 mrad). The efficiency at 70 keV for double reflection (10 percent), as required for adequate separation of the x-ray and neutron beams, is high enough for PHA requirements, but not for the XIS. Further optimization may be possible.

Research Organization:
Princeton Plasma Physics Lab. (PPPL), Princeton, NJ (United States)
Sponsoring Organization:
USDOE, Washington, DC (United States)
DOE Contract Number:
AC02-76CH03073
OSTI ID:
10110841
Report Number(s):
PPPL-3034; ITER/US-94/PH-07-14; ON: DE95006228
Resource Relation:
Other Information: PBD: Jan 1995
Country of Publication:
United States
Language:
English

Similar Records

ITER x-ray diagnostic studies
Journal Article · Thu Oct 01 00:00:00 EDT 1992 · Review of Scientific Instruments; (United States) · OSTI ID:10110841

Tokamak x ray diagnostic instrumentation
Technical Report · Thu Jan 01 00:00:00 EST 1987 · OSTI ID:10110841

Tokamak physics studies using x-ray diagnostic methods
Technical Report · Sun Mar 01 00:00:00 EST 1987 · OSTI ID:10110841