Production Test 105-524-A: Washer seal and seal leakage tests for the horizontal rod. Final report
Production Test 105-524-A authorized the installation of a washer seal on the ``A`` horizontal control rod at C Pile in order to determine the characteristics of this type seal when used on unlubricated rods. The most important characteristic to be observed during the test was the gas leakage rate. A qualitative study of the seal wear and radiation damage to the seal were also to be made. This document reports the conclusion of the test and discusses the results obtained.
- Research Organization:
- General Electric Co., Richland, WA (United States). Hanford Atomic Products Operation
- Sponsoring Organization:
- USDOE, Washington, DC (United States)
- DOE Contract Number:
- AC06-76RL01830
- OSTI ID:
- 10107532
- Report Number(s):
- HW--32185; ON: DE93003398
- Country of Publication:
- United States
- Language:
- English
Similar Records
Final report: Pile technology Development Test 105-571-A: Molded ribbed sphincter seal and seal leakage test for the ``C`` horizontal rod
Production Test No. 105-565-A: Horizontal rod conversion---old piles
Final report on Production Test 105-528-A -- Alteration of two C-Pile horizontal safety rods for temperature distribution control
Technical Report
·
Wed Jul 20 00:00:00 EDT 1955
·
OSTI ID:10104691
Production Test No. 105-565-A: Horizontal rod conversion---old piles
Technical Report
·
Sun Feb 14 23:00:00 EST 1954
·
OSTI ID:10104479
Final report on Production Test 105-528-A -- Alteration of two C-Pile horizontal safety rods for temperature distribution control
Technical Report
·
Thu Jun 11 00:00:00 EDT 1953
·
OSTI ID:10122326