Abstract

Through regulations, permitting or binding negotiations, Regulators establish requirements, limits, permit conditions and Notice of Construction (NOC) conditions with which the Office of River Protection (ORP) and the Tank Farm Contractor (TFC) must comply. Operating Specifications are technical limits which are set on a process to prevent injury to personnel, or damage to the facility or environment, The main purpose of this document is to provide specification limits and recovery actions for the TFC Environmental Surveillance Program at the Hanford Site. Specification limits are given for monitoring frequencies and permissible variation of readings from an established baseline or previous reading. The requirements in this document are driven by environmental considerations and data analysis issues, rather than facility design or personnel safety issues. This document is applicable to all single-shell tank (SST) and double-shell tank (DST) waste tanks, and the associated catch tanks and receiver tanks, and transfer systems. This Tank Farm Environmental Specifications Document (ESD) implements environmental-regulatory limits on the configuration and operation of the Hanford Tank Farms facility that have been established by Regulators. This ESD contains specific field operational limits and recovery actions for compliance with airborne effluent regulations and agreements, liquid effluents regulations and agreements, and environmentalmore » tank system requirements. The scope of this ESD is limited to conditions that have direct impact on Operations/Projects or that Operations Projects have direct impact upon. This document does not supercede or replace any Department of Energy (DOE) Orders, regulatory permits, notices of construction, or Regulatory agency agreements binding on the ORP or the TFC. Refer to the appropriate regulation, permit, or Notice of Construction for an inclusive listing of requirements.« less

Authors:
Publication Date:
Research Org.:
CH2M Hill Hanford Group, Inc., Richland, WA (United States)
Sponsoring Org.:
USDOE Office of Environmental Management (EM) (US)
OSTI Identifier:
812318
Report Number(s):
RPP-16922, Rev.0
EDT-637213; TRN: US0303346
DOE Contract Number:  
AC27-99RL14047
Resource Type:
Technical Report
Resource Relation:
Other Information: PBD: 26 Jun 2003
Country of Publication:
United States
Language:
English
Subject:
11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS; 12 MANAGEMENT OF RADIOACTIVE WASTES, AND NON-RADIOACTIVE WASTES FROM NUCLEAR FACILITIES; COMPLIANCE; DATA ANALYSIS; DESIGN; LIQUID WASTES; MONITORING; SAFETY; SPECIFICATIONS; STORAGE FACILITIES; RADIOACTIVE WASTE STORAGE; ENVIRONMENTAL QUALITY

Citation Formats

TIFFT, S R. TANK FARM ENVIRONMENTAL REQUIREMENTS. United States: N. p., 2003. Web. doi:10.2172/812318.
TIFFT, S R. TANK FARM ENVIRONMENTAL REQUIREMENTS. United States. https://doi.org/10.2172/812318
TIFFT, S R. 2003. "TANK FARM ENVIRONMENTAL REQUIREMENTS". United States. https://doi.org/10.2172/812318. https://www.osti.gov/servlets/purl/812318.
@article{osti_812318,
title = {TANK FARM ENVIRONMENTAL REQUIREMENTS},
author = {TIFFT, S R},
abstractNote = {Through regulations, permitting or binding negotiations, Regulators establish requirements, limits, permit conditions and Notice of Construction (NOC) conditions with which the Office of River Protection (ORP) and the Tank Farm Contractor (TFC) must comply. Operating Specifications are technical limits which are set on a process to prevent injury to personnel, or damage to the facility or environment, The main purpose of this document is to provide specification limits and recovery actions for the TFC Environmental Surveillance Program at the Hanford Site. Specification limits are given for monitoring frequencies and permissible variation of readings from an established baseline or previous reading. The requirements in this document are driven by environmental considerations and data analysis issues, rather than facility design or personnel safety issues. This document is applicable to all single-shell tank (SST) and double-shell tank (DST) waste tanks, and the associated catch tanks and receiver tanks, and transfer systems. This Tank Farm Environmental Specifications Document (ESD) implements environmental-regulatory limits on the configuration and operation of the Hanford Tank Farms facility that have been established by Regulators. This ESD contains specific field operational limits and recovery actions for compliance with airborne effluent regulations and agreements, liquid effluents regulations and agreements, and environmental tank system requirements. The scope of this ESD is limited to conditions that have direct impact on Operations/Projects or that Operations Projects have direct impact upon. This document does not supercede or replace any Department of Energy (DOE) Orders, regulatory permits, notices of construction, or Regulatory agency agreements binding on the ORP or the TFC. Refer to the appropriate regulation, permit, or Notice of Construction for an inclusive listing of requirements.},
doi = {10.2172/812318},
url = {https://www.osti.gov/biblio/812318}, journal = {},
number = ,
volume = ,
place = {United States},
year = {Thu Jun 26 00:00:00 EDT 2003},
month = {Thu Jun 26 00:00:00 EDT 2003}
}