Models for Automated Tube Performance Calculations
High power radio-frequency systems, as typically used in fusion research devices, utilize vacuum tubes. Evaluation of vacuum tube performance involves data taken from tube operating curves. The acquisition of data from such graphical sources is a tedious process. A simple modeling method is presented that will provide values of tube currents for a given set of element voltages. These models may be used as subroutines in iterative solutions of amplifier operating conditions for a specific loading impedance.
- Research Organization:
- Princeton Plasma Physics Lab. (PPPL), Princeton, NJ (United States)
- Sponsoring Organization:
- USDOE Office of Science (US)
- DOE Contract Number:
- AC02-76CH03073
- OSTI ID:
- 809956
- Report Number(s):
- PPPL-3763; TRN: US0302656
- Resource Relation:
- Other Information: PBD: 12 Dec 2002
- Country of Publication:
- United States
- Language:
- English
Similar Records
A multi-channel, optically coupled spark gap monitor system
High-performance silicon field emitter arrays for microwave power tube cathodes
A revisit to self-excited push pull vacuum tube radio frequency oscillator for ion sources and power measurements
Conference
·
Thu Oct 01 00:00:00 EDT 1987
·
OSTI ID:809956
High-performance silicon field emitter arrays for microwave power tube cathodes
Conference
·
Tue Dec 31 00:00:00 EST 1996
·
OSTI ID:809956
A revisit to self-excited push pull vacuum tube radio frequency oscillator for ion sources and power measurements
Journal Article
·
Fri Apr 15 00:00:00 EDT 2016
· Review of Scientific Instruments
·
OSTI ID:809956
+2 more