skip to main content
OSTI.GOV title logo U.S. Department of Energy
Office of Scientific and Technical Information

Title: Double Shell Tank (DST) Transfer Pump Subsystem Specification

Technical Report ·
DOI:https://doi.org/10.2172/805952· OSTI ID:805952

This specification establishes the performance requirements and provides the references to the requisite codes and standards to be applied during the design of the Double-Shell Tank (DST) Transfer Pump Subsystem that supports the first phase of waste feed delivery (WFD). The DST Transfer Pump Subsystem consists of a pump for supernatant and/or slurry transfer for the DSTs that will be retrieved during the Phase 1 WFD operations. This system is used to transfer low-activity waste (LAW) and high-level waste (HLW) to designated DST staging tanks. It also will deliver blended LAW and HLW feed from these staging tanks to the River Protection Project (RPP) Waste Treatment Plant where it will be processed into an immobilized waste form. This specification is intended to be the basis for new projects/installations (W-521, etc.). This specification is not intended to retroactively affect previously established project design criteria without specific direction by the program.

Research Organization:
FFS (US)
Sponsoring Organization:
USDOE Office of Environmental Management (EM) (US)
DOE Contract Number:
AC06-96RL13200
OSTI ID:
805952
Report Number(s):
HNF-4162, Rev.1; ECN-644521; TRN: US0301075
Resource Relation:
Other Information: PBD: 18 Jan 2001
Country of Publication:
United States
Language:
English

Similar Records

Double Shell Tank (DST) Transfer Pump Subsystem Specification
Technical Report · Mon Mar 27 00:00:00 EST 2000 · OSTI ID:805952

Double Shell Tank (DST) Transfer Valving Subsystem Specification
Technical Report · Wed Mar 22 00:00:00 EST 2000 · OSTI ID:805952

Double Shell Tank (DST) Utilities Specification
Technical Report · Thu Apr 27 00:00:00 EDT 2000 · OSTI ID:805952