Demonstration of a Solution Film Leak Test Technique and Equipment for the S00645 Canister Closure
The purpose of this effort was to demonstrate that the SFT technique, when adapted to a DWPF canister nozzle, is capable of detecting leaks not meeting the Waste Acceptance Product Specifications (WAPS) acceptance criterion.
- Research Organization:
- Savannah River Site (SRS), Aiken, SC (United States)
- Sponsoring Organization:
- US Department of Energy (US)
- DOE Contract Number:
- AC09-96SR18500
- OSTI ID:
- 13810
- Report Number(s):
- WSRC-TR-99-00192; TRN: US0110792
- Resource Relation:
- Other Information: PBD: 7 Oct 1999
- Country of Publication:
- United States
- Language:
- English
Similar Records
Defense Waste Processing Facility Canister Closure Weld Current Validation Testing
Initial results from the canistered waste forms produced during the first campaign of the DWPF Startup Test Program
An opportunity for demonstrating compliance with the waste acceptance preliminary specifications on foreign materials within DWPF (Defense Waste Processing Facility) canistered waste forms
Technical Report
·
Mon Jan 29 00:00:00 EST 2018
·
OSTI ID:13810
Initial results from the canistered waste forms produced during the first campaign of the DWPF Startup Test Program
Conference
·
Sun Jan 01 00:00:00 EST 1995
·
OSTI ID:13810
An opportunity for demonstrating compliance with the waste acceptance preliminary specifications on foreign materials within DWPF (Defense Waste Processing Facility) canistered waste forms
Conference
·
Mon Jan 01 00:00:00 EST 1990
·
OSTI ID:13810