Title: Wire Measurement of Impedance of an X-Band Accelerating Structure

Technical Report ·
DOI:https://doi.org/10.2172/833027· OSTI ID:833027

Several tens of thousands of accelerator structures will be needed for the next generation of normal conducting linear colliders known as the GLC/NLC (Global Linear Collider/Next Linear Collider). To prevent the beam being driven into a disruptive BBU (Beam Break-Up) mode or at the very least, the emittance being significantly diluted, it is important to damp down the wakefield left by driving bunches to a manageable level. Manufacturing errors and errors in design need to be measured and compared with prediction. In this paper a bench-top method of measuring transverse impedances in X-band accelerating structures is described. Utilizing an off-axis wire the S parameters are measured and converted to impedance. Measurements in a damped and detuned structure built for GLC/NLC are presented and the results are discussed.

Research Organization:
SLAC National Accelerator Lab., Menlo Park, CA (United States)
Sponsoring Organization:
USDOE Office of Science (US)
DOE Contract Number:
AC03-76SF00515
OSTI ID:
833027
Report Number(s):
SLAC-PUB-10685; TRN: US0406505
Resource Relation:
Other Information: PBD: 2 Sep 2004
Country of Publication:
United States
Language:
English