Title: Target Window Reliability

Technical Report ·
DOI:https://doi.org/10.2172/1238127· OSTI ID:1238127
 [1]
  1. Los Alamos National Lab. (LANL), Los Alamos, NM (United States)

The target window design implemented and tested in experiments at ANL have performed without failure for the available beam of 6 mm FWHM on a 12 mm diameter target. However, scaling that design to a 25 mm diameter target size for a 12 mm FWHM beam has proven problematic. Combined thermal and mechanical (pressure induced) stresses and strains are too high to maintain the small coolant gaps and provide adequate fatigue lifetime.