Electrostatic Discharge testing of propellants and primers
This report presents the results of testing of selected propellants and primers to Electrostatic Discharge (ESD) characteristic of the human body. It describes the tests and the fixturing built to accommodate loose material (propellants) and the packed energetic material of the primer. The results indicate that all powders passed and some primers, especially the electric primers, failed to pass established requirements which delineate insensitive energetic components. This report details the testing of components and materials to four ESD environments (Standard ESD, Severe ESD, Modified Standard ESD, and Modified Severe ESD). The purpose of this study was to collect data based on the customer requirements as defined in the Sandia Environmental Safety & Health (ES&H) Manual, Chapter 9, and to define static sensitive and insensitive propellants and primers.
- Research Organization:
- Sandia National Lab. (SNL-NM), Albuquerque, NM (United States)
- Sponsoring Organization:
- USDOE, Washington, DC (United States)
- DOE Contract Number:
- AC04-94AL85000
- OSTI ID:
- 10131328
- Report Number(s):
- SAND-92-2416; ON: DE94007840; BR: GB0103012
- Resource Relation:
- Other Information: PBD: Feb 1994
- Country of Publication:
- United States
- Language:
- English
Similar Records
Sandia severe electrostatic discharge tester: Version 3 (SSET), Serial Number: 1
Electrostatic discharge study of HMX actuators