  1. Graph theory and nighttime imagery based microgrid design

    Reducing the duration and frequency of blackouts in remote communities poses an engineering challenge for grid operators. Outage effects can also be mitigated locally through microgrids. This paper develops a systematic procedure to account for these challenges by creating microgrids prioritizing high value assets within vulnerable communities. Nighttime satellite imagery is used to identify vulnerable communities. Using an asset classification and rating system, multi-asset clusters within these communities are prioritized. Infrastructure data, geographic information systems, satellite imagery, and spectral clustering are used to form and rank microgrid candidates. A microgrid sizing algorithm is included to guide through the microgrid designmore » process. Finally, an application of the methodology is presented using real event, location, and asset data.« less
  2. Switch Location Identification for Integrating a Distant Photovoltaic Array Into a Microgrid

    Many Electric Power Systems (EPS) already include geographically dispersed photovoltaic (PV) systems. These PV systems may not be co-located with highest-priority loads and, thus, easily integrated into a microgrid; rather PV systems and priority loads may be far away from one another. Furthermore, because of the existing EPS configuration, non-critical loads between the distant PV and critical load(s) cannot be selectively disconnected. To achieve this, the proposed approach finds ideal switch locations by first defining the path between the critical load and a large PV system, then identifies all potential new switch locations along this path, and finally discovers switchmore » locations for a particular budget by finding the ones the produce the lowest Loss of Load Probability (LOLP), which is when load exceed generation. Discovery of the switches with the lowest LOLP involves a Particle Swarm Optimization (PSO) implementation. The objective of the PSO is to minimize the microgird’s LOLP. The approach assumes dynamic microgrid operations, where both the critical and non-critical loads are powered during the day and only the critical load at night. To evaluate the approach, this paper includes a case study that uses the topology and Advanced Metering Infrastructure (AMI) data from an actual EPS. For this example, the assessment found new switch locations that reduced the LOLP by up to 50% for two distant PV location scenarios.« less
  3. Geospatial Assessment Methodology to Estimate Power Line Restoration Access Vulnerabilities After a Hurricane in Puerto Rico

    Limited access to transmission lines after a major contingency event can inhibit restoration efforts. After Hurricane Maria, for example, flooding and landslides damaged roads and thus limited travel. Transmission lines are also often situated far from maintained roadways, further limiting the ability to access and repair them. Therefore, this paper proposes a methodology for assessing Puerto Rico’s infrastructure (i.e., roads and transmission lines) to identify potentially hard to reach areas due to natural risks or distance to roads. The approach uses geographic information system (GIS) data to define vulnerable areas, that may experience excessive restoration times. The methodology also usesmore » graph theory analysis to find transmission lines with high centrality (or importance). Comparison of these important transmission lines with the vulnerability results found that many reside near roads that are at risk for landslides or floods.« less
  4. Uncontrolled Electric Vehicle Charging Impacts on Distribution Electric Power Systems with Primarily Residential, Commercial or Industrial Loads

    An increase in Electric Vehicles (EV) will result in higher demands on the distribution electric power systems (EPS) which may result in thermal line overloading and low voltage violations. To understand the impact, this work simulates two EV charging scenarios (home- and work-dominant) under potential 2030 EV adoption levels on 10 actual distribution feeders that support residential, commercial, and industrial loads. The simulations include actual driving patterns of existing (non-EV) vehicles taken from global positioning system (GPS) data. The GPS driving behaviors, which explain the spatial and temporal EV charging demands, provide information on each vehicles travel distance, dwell locations,more » and dwell durations. Then, the EPS simulations incorporate the EV charging demands to calculate the power flow across the feeder. Simulation results show that voltage impacts are modest (less than 0.01 p.u.), likely due to robust feeder designs and the models only represent the high-voltage (“primary”) system components. Line loading impacts are more noticeable, with a maximum increase of about 15%. Additionally, the feeder peak load times experience a slight shift for residential and mixed feeders (≈1 h), not at all for the industrial, and 8 h for the commercial feeder.« less
  5. Volt-Var Curve Reactive Power Control Requirements and Risks for Feeders with Distributed Roof-Top Photovoltaic Systems

    The benefits and risks associated with Volt-Var Curve (VVC) control for management of voltages in electric feeders with distributed, roof-top photovoltaic (PV) can be defined using a stochastic hosting capacity analysis methodology. Although past work showed that a PV inverter’s reactive power can improve grid voltages for large PV installations, this study adds to the past research by evaluating the control method’s impact (both good and bad) when deployed throughout the feeder within small, distributed PV systems. The stochastic hosting capacity simulation effort iterated through hundreds of load and PV generation scenarios and various control types. The simulations also testedmore » the impact of VVCs with tampered settings to understand the potential risks associated with a cyber-attack on all of the PV inverters scattered throughout a feeder. The simulation effort found that the VVC can have an insignificant role in managing the voltage when deployed in distributed roof-top PV inverters. This type of integration strategy will result in little to no harm when subjected to a successful cyber-attack that alters the VVC settings.« less
  6. Evaluation of global horizontal irradiance to plane-of-array irradiance models at locations across the United States

    We report an evaluation of the accuracy of combinations of models that estimate plane-of-array (POA) irradiance from measured global horizontal irradiance (GHI). This estimation involves two steps: 1) decomposition of GHI into direct and diffuse horizontal components and 2) transposition of direct and diffuse horizontal irradiance (DHI) to POA irradiance. Measured GHI and coincident measured POA irradiance from a variety of climates within the United States were used to evaluate combinations of decomposition and transposition models. A few locations also had DHI measurements, allowing for decoupled analysis of either the decomposition or the transposition models alone. Results suggest that decompositionmore » models had mean bias differences (modeled versus measured) that vary with climate. Transposition model mean bias differences depended more on the model than the location. Lastly, when only GHI measurements were available and combinations of decomposition and transposition models were considered, the smallest mean bias differences were typically found for combinations which included the Hay/Davies transposition model.« less