On February 28, 1992, at approximately 1053 hours, a water hammer occurred at the 242-A Evaporator Facility located in the 200 East Area of the Hanford Site. The facility's Raw Water/Used Raw Water (RW/URW) system was undergoing operational testing at the time of the event. While trying to establish system water pressure, a downstream pressure control valve was overcome by water pressure and abruptly shut. Approximately 2300 gal/min of raw water flow was established before the valve closed. Supply water pressure was determined to be approximately 105 psig. During preliminary damage assessments a pressure gauge was found overranged and water was observed leaking from various components. Detailed evaluations are being conducted to assess potential damage to the EC-1 Condenser and other equipment associated with the RW/URW systems.

Research Organization:
Westinghouse Hanford Co., Richland, WA (United States)
Sponsoring Organization:
USDOE; USDOE, Washington, DC (United States)
DOE Contract Number:
AC06-87RL10930
OSTI ID:
7008811
Report Number(s):
WHC-SP-0822; ON: DE93007031
Country of Publication:
United States
Language:
English