Comparison of BEACON and COMPARE reactor cavity subcompartment analyses
In this study, a more advanced best-estimate containment code, BEACON-MOD3A, was ued to calculate force and moment loads resulting from a high-energy blowdown for two reactor cavity geometries previously analyzed with the licensing computer code COMPARE-MOD1A. The BEACON force and moment loads were compared with the COMPARE results to determine the safety margins provided by the COMPARE code. The forces and moments calculated by the codes were found to be different, although not in any consistent manner, for the two reactor cavity geometries studied. Therefore, generic summary statements regarding margins cannot be made because of the effects of the detailed physical configuration. However, differences in the BEACON and COMPARE calculated forces and moments can be attributed to differences in the modeling assumptions used in the codes and the analyses.