Evaluating criticality safety of TRU waste with NDA measurements and risk analyses
Conference
·
OSTI ID:68748
The criticality safety of {sup 239}Pu in 55-gal. drums stored in TRU waste containers (concrete culverts) was evaluated using NDA neutron and gamma measurements and risk analyses. The neutron measurements yielded a {sup 239}Pu mass and k{sub eff} for a culvert, which contains up to 14 drums. The gamma measurements helped reveal and correct for any interfering neutron sources in the waste. Conservation probabilistic risk analyses were developed for both drums and culverts.
- Research Organization:
- Los Alamos National Lab. (LANL), Los Alamos, NM (United States)
- OSTI ID:
- 68748
- Report Number(s):
- LA-12556-C; CONF-9205206-; ON: DE95000557; TRN: 95:002821-0013
- Resource Relation:
- Conference: DOE nuclear criticality safety technology project workshop, Gaithersburg, MD (United States), 12-14 May 1992; Other Information: PBD: Sep 1994; Related Information: Is Part Of Proceedings of the first annual Nuclear Criticality Safety Technology Project; Rutherford, D.A. [comp.]; PB: 251 p.
- Country of Publication:
- United States
- Language:
- English
Similar Records
Confirming criticality safety of TRU waste with neutron measurements and risk analyses
Confirming criticality safety of TRU waste with neutron measurements and risk analyses
Criticality assessment of TRU burial ground culverts
Conference
·
Wed Jan 01 00:00:00 EST 1992
·
OSTI ID:68748
Confirming criticality safety of TRU waste with neutron measurements and risk analyses
Conference
·
Wed Apr 01 00:00:00 EST 1992
·
OSTI ID:68748
Criticality assessment of TRU burial ground culverts
Technical Report
·
Wed Sep 26 00:00:00 EDT 1990
·
OSTI ID:68748