skip to main content
OSTI.GOV title logo U.S. Department of Energy
Office of Scientific and Technical Information

Title: Low aspect ratio transonic rotors: Part 1. Baseline design and performance

Journal Article · · Journal of Turbomachinery; (United States)
DOI:https://doi.org/10.1115/1.2929226· OSTI ID:6474451
 [1];  [2]
  1. Wright Lab., Wright-Patterson AFB, OH (United States)
  2. GE Aircraft Engines, Cincinnati, OH (United States)

The analytical design and experimental test of a single-stage transonic axial-flow compressor are described. This design is the baseline of a compressor design study in which several blade design parameters have been systematically varied to determine their independent effects on compressor performance. The baseline design consisted of ruggedizing an existing compressor design that demonstrated outstanding aerodynamic performance, to correct some undesirable aeromechanical characteristics. The design study was performed by varying only one design parameter at a time, keeping the other design variables as close as possible to the baseline design. Specific design parameters of interest were those for which very few data were available to determine their sensitivity on compressor performance. This paper describes the baseline compressor design and its experimental performance. A detailed definition and flow analysis of the baseline design test point (used as the basis for all subsequent design variations) are provided.

OSTI ID:
6474451
Journal Information:
Journal of Turbomachinery; (United States), Vol. 115:2; ISSN 0889-504X
Country of Publication:
United States
Language:
English