skip to main content
OSTI.GOV title logo U.S. Department of Energy
Office of Scientific and Technical Information

Title: Electron-beam-pinch experiment at Harry Diamond Laboratories: Providing for a high-dose-rate flash x-ray facility for transient radiation effects on electronics (TREE) testing of pieceparts. Final report, May-Jul 90

Technical Report ·
OSTI ID:5148242

The peak photon-radiation dose rate of the High-Intensity Flash X-Ray facility has been increased by at least a factor of five through the use of custom beam-pinching hardware. With this hardware, the facility can now routinely provide a dose rate of 2.7 times 10 to the 11th power rads(Si)/s, at a distance of 1/4 in. from the drift-tube face, while providing excellent radial drop-off to minimized irradiation of items surrounding the device under test. The experimental results show the optimum operating parameters of the beam-pinching hardware to be a drift-tube length equal to 6 cm with an internal nitrogen gas pressure of 0.1 Torr.

Research Organization:
Harry Diamond Labs., Adelphi, MD (United States)
OSTI ID:
5148242
Report Number(s):
AD-A-239558/0/XAB; HDL-TM-91-11
Country of Publication:
United States
Language:
English