skip to main content
OSTI.GOV title logo U.S. Department of Energy
Office of Scientific and Technical Information

Title: Study of multispectral convolution scatter correction in high resolution PET

Conference ·
OSTI ID:513209
;  [1];  [2]
  1. Univ. of Sherbrooke, Quebec (Canada)
  2. UCL, Louvain-la-neuve (Belgium)

PET images acquired with a high resolution scanner based on arrays of small discrete detectors are obtained at the cost of low sensitivity and increased detector scatter. It has been postulated that these limitations can be overcome by using enlarged discrimination windows to include more low energy events and by developing more efficient energy-dependent methods to correct for scatter. In this work, we investigate one such method based on the frame-by-frame scatter correction of multispectral data. Images acquired in the conventional, broad and multispectral window modes were processed by the stationary and nonstationary consecutive convolution scatter correction methods. Broad and multispectral window acquisition with a low energy threshold of 129 keV improved system sensitivity by up to 75% relative to conventional window with a {approximately}350 keV threshold. The degradation of image quality due to the added scatter events can almost be fully recovered by the subtraction-restoration scatter correction. The multispectral method was found to be more sensitive to the nonstationarity of scatter and its performance was not as good as that of the broad window. It is concluded that new scatter degradation models and correction methods need to be established to fully take advantage of multispectral data.

OSTI ID:
513209
Report Number(s):
CONF-961123-; TRN: 97:014262
Resource Relation:
Conference: Institute of Electrical and Electronic Engineers (IEEE) nuclear science symposium and medical imaging conference, Anaheim, CA (United States), 2-9 Nov 1996; Other Information: PBD: 1996; Related Information: Is Part Of 1996 IEEE nuclear science symposium - conference record. Volumes 1, 2 and 3; Del Guerra, A. [ed.]; PB: 2138 p.
Country of Publication:
United States
Language:
English

Similar Records

Energy dependence of nonstationary subtraction-restoration scatter correction in high resolution PET
Conference · Tue Dec 31 00:00:00 EST 1996 · OSTI ID:513209

Energy dependence of scatter components in multispectral PET imaging
Journal Article · Wed Mar 01 00:00:00 EST 1995 · IEEE Transactions on Medical Imaging · OSTI ID:513209

Object and detector scatter function dependence on energy and position in high resolution PET
Journal Article · Tue Aug 01 00:00:00 EDT 1995 · IEEE Transactions on Nuclear Science · OSTI ID:513209