Title: Methodology and Software for Gross Defect Detection of Spent Nuclear Fuel at the Atucha-I Reactor

Conference ·
DOI:https://doi.org/10.13182/NT14-63· OSTI ID:22531329
; ;  [1];  [2];  [3]
  1. Lawrence Livermore National Laboratory, 7000 East Avenue, Livermore, CA 94550 (United States)
  2. Brazilian-Argentine Agency for Accounting and Control of Nuclear Materials, Avenida Rio Branco, 123/Grupo 515- Centro, CEP: 20040-005, Rio de Janeiro (Brazil)
  3. National Regulatory Authority - Argentina, Av. Del Libertador 8250, (1429) Buenos Aires (Argentina)

At the Atucha-I pressurized heavy water reactor in Argentina, fuel assemblies in the spent fuel pools are stored by suspending them in two vertically stacked layers. This introduces the unique problem of verifying the presence of fuel in either layer without physically moving the fuel assemblies. Since much of the fuel is very old, Cerenkov viewing devices are often not very useful even for the top layer. Given that the facility uses both natural uranium and slightly enriched uranium at 0.85 w% {sup 235}U, and has been in operation since 1974, a wide range of burnups and cooling times can exist in any given pool. A spent fuel neutron counting tool consisting of a fission chamber, SFNC, has been used at the site to verify the presence of fuel up to burnups of 8000 MWd/t. At higher discharge burnups to levels up 11,000 MWd/t, the existing signal processing software of the tool was found to fail due to non-linearity of the source term with burnup. A new Graphical User Interface software package based on the LabVIEW platform was developed to predict expected neutron signals covering all ranges of burnups and cooling times and establish maps of expected signals at various pool locations. The algorithm employed in the software uses a set of transfer functions in a 47-energy group structure which are coupled with a 47-energy group neutron source spectrum based on various cooling times and burnups for each of the two enrichment levels. The database of the software consists of these transfer functions for the three different inter-assembly pitches that the fuel is stored in at the site. The transfer functions were developed for a 6 by 6 matrix of fuel assemblies with the detector placed at the center surrounded by four near neighbors, eight next nearest neighbors and so on for the 36 assemblies. These calculations were performed using Monte Carlo radiation transport methods. The basic methodology consisted of starting sources in each of the assemblies and tallying the contribution to the detector by a single neutron in each of the 47 energy groups used. Thus for the single existing symmetric pitch in the pools, where the vertical and horizontal separations are equal, only 6 sets of transfer functions are required. For the two asymmetrical pitches, nine sets of transfer functions are stored. In addition, source spectra at burnups ranging from 4000 to 20000 MWd/t and cooling times up to 40 years are stored. These source terms were established based on CANDU 37-rod fuel that is very similar to the Atucha fuel. Linear interpolation is used by the software for both burnup and cooling time to establish source terms at any intermediate condition. Using the burnup, cooling time and initial enrichment of the surrounding assemblies a set of source strengths in the 47-group structure for each of the 36 assemblies is established and multiplied group-wise with the appropriate transfer function set. The grand total over the 47 groups for all 36 assemblies is the predicted signal at the detector. The software was initially calibrated against a set of typically 5-6 measurements chosen from among the measured data at each level of the six pools and calibration factors were established. The set used for calibration is chosen such that it is fairly representative of the range of spent fuel assembly characteristics present in each level. Once established, these calibration factors can be repeatedly used for verification purposes. Recalibration will be required if the hardware or pool configurations has changed. It will also be required if a long enough time has elapsed since they were established thus making a cooling time correction necessary. The objective of the inspection is to detect missing fuel from one or more nearest neighbors of the detector. During the verification mode of the software, the predicted and measured signals are compared and the inspector is alerted if the difference between the two signals is beyond a set tolerance limit. Based on the uncertainties associated with both the calculations and measurements, a lower limit of the tolerance will be 15% with an upper limit of 20%. For the most part a 20% tolerance limit will be able to detect a missing assembly since in the vast majority of cases the drop in signal due to a single missing nearest neighbor assembly will be in the range 24-27%. The software was benchmarked against an extensive set of measured data taken at the site in 2004. Overall, 326 data points were examined and the prediction of the calibrated software was compared to the measurements within a set tolerance of ±20%. Of these, 283 of the predicted signals representing 87% of the total matched the measured data within ±10%. A further 27 or 8% were in the range of ±10-15% and 8 or 2.5% were in the range of ±15-20%. Thus, 97.5% of the data matched the measurements within the set tolerance limit of 20%, with 95% matching measured data with the lowest allowed tolerance limit of ±15%. The remaining 2.5% had measured signals that were very different from those at locations with very similar surrounding assemblies and the cause of these discrepancies could not be ascertained from the measurement logs. In summary, 97.5% of the predictions matched the measurements within the set 20% tolerance limit providing proof of the robustness of the software. This software package linked to SFNC will be deployed at the site and will enhance the capability of gross defect verification for the whole range of burnup, cooling time and initial enrichments of the spent fuel being discharged into the various pools at the Atucha-I reactor site.

Research Organization:
Institute of Electrical and Electronics Engineers - IEEE, 3 Park Avenue, 17th Floor, New York, N.Y. 10016-5997 (United States)
OSTI ID:
22531329
Report Number(s):
ANIMMA-2015-IO-281; TRN: US16V0458102270
Resource Relation:
Journal Volume: 192; Journal Issue: 1; Conference: ANIMMA 2015: 4. International Conference on Advancements in Nuclear Instrumentation Measurement Methods and their Applications, Lisboa (Portugal), 20-24 Apr 2015; Other Information: Country of input: France
Country of Publication:
United States
Language:
English