Title: SU-C-207-04: Reconstruction Artifact Reduction in X-Ray Cone Beam CT Using a Treatment Couch Model

Journal Article · · Medical Physics
DOI:https://doi.org/10.1118/1.4923835· OSTI ID:22486576
; ; ; ;  [1]
  1. University of Maryland School of Medicine, Baltimore, MD (United States)

Purpose: to mitigate artifacts induced by the presence of the RT treatment couch in on-board CBCT and improve image quality Methods: a model of a Varian IGRT couch is constructed using a CBCT scan of the couch in air. The model is used to generate a set of forward projections (FP) of the treatment couch at specified gantry angles. The model couch forward projections are then used to process CBCT scan projections which contain the couch in addition to the scan object (Catphan phantom), in order to remove the attenuation component of the couch at any given gantry angle. Prior to pre-processing with the model FP, the Catphan projection data is normalized to an air scan with bowtie filter. The filtered Catphan projections are used to reconstruct the CBCT with an in-house FDK algorithm. The artifact reduction in the processed CBCT scan is assessed visually, and the image quality improvement is measured with the CNR over a few selected ROIs of the Catphan modules. Results: Sufficient match between the forward projected data and the x-ray projections is achieved to allow filtering in attenuation space. Visual improvement of the couch induced artifacts is achieved, with a moderate expense of CNR. Conclusion: Couch model-based correction of CBCT projection data has a potential for qualitative improvement of clinical CBCT scans, without requiring position specific correction data. The technique could be used to produce models of other artifact inducing devices, such as immobilization boards, and reduce their impact on patient CBCT images.

OSTI ID:
22486576
Journal Information:
Medical Physics, Vol. 42, Issue 6; Other Information: (c) 2015 American Association of Physicists in Medicine; Country of input: International Atomic Energy Agency (IAEA); ISSN 0094-2405
Country of Publication:
United States
Language:
English

Similar Records

Shading correction for on-board cone-beam CT in radiation therapy using planning MDCT images
Journal Article · Fri Oct 15 00:00:00 EDT 2010 · Medical Physics · OSTI ID:22486576

Generation of virtual monochromatic CBCT from dual kV/MV beam projections
Journal Article · Sun Dec 15 00:00:00 EST 2013 · Medical Physics · OSTI ID:22486576

Generation of virtual monochromatic CBCT from dual kV/MV beam projections
Journal Article · Sun Dec 15 00:00:00 EST 2013 · Medical Physics · OSTI ID:22486576