skip to main content

Title: Off-normal and failure condition analysis of the MITICA negative-ion accelerator

The negative-ion accelerator for the MITICA neutral beam injector has been designed and optimized in order to reduce the thermo-mechanical stresses in all components below limits compatible with the required fatigue life. However, deviation from the expected beam performances can be caused by “off-normal” operating conditions of the accelerator. The purpose of the present work is to identify and analyse all the “off-normal” operating conditions, which could possibly become critical in terms of thermo-mechanical stresses or of degradation of the optical performances of the beam.
Authors:
;  [1] ;  [2] ; ; ; ; ; ;  [1]
  1. Consorzio RFX, (CNR, ENEA, INFN, Università di Padova, Acciaierie Venete SpA), Corso Stati Uniti 4, 35127 Padova (Italy)
  2. (Italy)
Publication Date:
OSTI Identifier:
22482975
Resource Type:
Journal Article
Resource Relation:
Journal Name: Review of Scientific Instruments; Journal Volume: 87; Journal Issue: 2; Other Information: (c) 2015 EURATOM; Country of input: International Atomic Energy Agency (IAEA)
Country of Publication:
United States
Language:
English
Subject:
46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND TECHNOLOGY; ACCELERATORS; ANIONS; BEAMS; DESIGN; FAILURES; FATIGUE; PERFORMANCE; STRESSES