Salvage Stereotactic Body Radiation Therapy (SBRT) for Local Failure After Primary Lung SBRT
Purpose: Local failure after definitive stereotactic body radiation therapy (SBRT) for early-stage non-small cell lung cancer (NSCLC) is uncommon. We report the safety and efficacy of SBRT for salvage of local failure after previous SBRT with a biologically effective dose (BED) of ≥100 Gy{sub 10}. Methods and Materials: Using an institutional review board–approved lung SBRT registry, we identified all patients initially treated for early-stage NSCLC between August 2004 and January 2012 who received salvage SBRT for isolated local failure. Failure was defined radiographically and confirmed histologically unless contraindicated. All patients were treated on a Novalis/BrainLAB system using ExacTrac for image guidance, and received a BED of ≥100 Gy{sub 10} for each SBRT course. Tumor motion control involved a Bodyfix vacuum system for immobilization along with abdominal compression. Results: Of 436 patients treated from August 2004 through January 2012, we identified 22 patients with isolated local failure, 10 of whom received SBRT for salvage. The median length of follow-up was 13.8 months from salvage SBRT (range 5.3-43.5 months). Median tumor size was 3.4 cm (range 1.7-4.8 cm). Two of the 10 lesions were “central” by proximity to the mediastinum, but were outside the zone of the proximal bronchial tree. Since completing salvage, 3 patients are alive and without evidence of disease. A fourth patient died of medical comorbidities without recurrence 13.0 months after salvage SBRT. Two patients developed distant disease only. Four patients had local failure. Toxicity included grade 1-2 fatigue (3 patients) and grade 1-2 chest wall pain (5 patients). There was no grade 3-5 toxicity. Conclusions: Repeat SBRT with a BED of ≥100 Gy{sub 10} after local failure in patients with early-stage medically inoperable NSCLC was well tolerated in this series and may represent a viable salvage strategy in select patients with peripheral tumors ≤5 cm.
- OSTI ID:
- 22423826
- Journal Information:
- International Journal of Radiation Oncology, Biology and Physics, Vol. 90, Issue 2; Other Information: Copyright (c) 2014 Elsevier Science B.V., Amsterdam, The Netherlands, All rights reserved.; Country of input: International Atomic Energy Agency (IAEA); ISSN 0360-3016
- Country of Publication:
- United States
- Language:
- English
Similar Records
30 Gy or 34 Gy? Comparing 2 Single-Fraction SBRT Dose Schedules for Stage I Medically Inoperable Non-Small Cell Lung Cancer
SU-E-T-289: Dose-Volume-Effect Relationships for Lung Cancer Patients Treated with SBRT On a Prospective Protocol