skip to main content
OSTI.GOV title logo U.S. Department of Energy
Office of Scientific and Technical Information

Title: Noninvasive referencing of intraocular tumors for external beam radiation therapy using optical coherence tomography: A proof of concept

Journal Article · · Medical Physics
DOI:https://doi.org/10.1118/1.4885975· OSTI ID:22409868
; ;  [1]; ;  [2]
  1. Berne University of Applied Sciences, HuCE OptoLab, 2501 (Switzerland)
  2. Department of Radiation Oncology, Inselspital, Bern University Hospital, University of Bern, Bern 3010 (Switzerland)

Purpose: External beam radiation therapy is currently considered the most common treatment modality for intraocular tumors. Localization of the tumor and efficient compensation of tumor misalignment with respect to the radiation beam are crucial. According to the state of the art procedure, localization of the target volume is indirectly performed by the invasive surgical implantation of radiopaque clips or is limited to positioning the head using stereoscopic radiographies. This work represents a proof-of-concept for direct and noninvasive tumor referencing based on anterior eye topography acquired using optical coherence tomography (OCT). Methods: A prototype of a head-mounted device has been developed for automatic monitoring of tumor position and orientation in the isocentric reference frame for LINAC based treatment of intraocular tumors. Noninvasive tumor referencing is performed with six degrees of freedom based on anterior eye topography acquired using OCT and registration of a statistical eye model. The proposed prototype was tested based on enucleated pig eyes and registration accuracy was measured by comparison of the resulting transformation with tilt and torsion angles manually induced using a custom-made test bench. Results: Validation based on 12 enucleated pig eyes revealed an overall average registration error of 0.26 ± 0.08° in 87 ± 0.7 ms for tilting and 0.52 ± 0.03° in 94 ± 1.4 ms for torsion. Furthermore, dependency of sampling density on mean registration error was quantitatively assessed. Conclusions: The tumor referencing method presented in combination with the statistical eye model introduced in the past has the potential to enable noninvasive treatment and may improve quality, efficacy, and flexibility of external beam radiotherapy of intraocular tumors.

OSTI ID:
22409868
Journal Information:
Medical Physics, Vol. 41, Issue 8; Other Information: (c) 2014 American Association of Physicists in Medicine; Country of input: International Atomic Energy Agency (IAEA); ISSN 0094-2405
Country of Publication:
United States
Language:
English

Similar Records

Optical eye tracking system for real-time noninvasive tumor localization in external beam radiotherapy
Journal Article · Fri May 15 00:00:00 EDT 2015 · Medical Physics · OSTI ID:22409868

Statistical Modeling of the Eye for Multimodal Treatment Planning for External Beam Radiation Therapy of Intraocular Tumors
Journal Article · Thu Nov 15 00:00:00 EST 2012 · International Journal of Radiation Oncology, Biology and Physics · OSTI ID:22409868

Intraocular cyclophotocoagulation. Histopathologic evaluation in primates
Journal Article · Fri Nov 01 00:00:00 EST 1985 · Arch. Ophthalmol. (Chicago); (United States) · OSTI ID:22409868