skip to main content

SciTech ConnectSciTech Connect

Title: Neutron dosimetry in solid water phantom

The neutron spectra, the Kerma and the absorbed dose due to neutrons were estimated along the incoming beam in a solid water phantom. Calculations were carried out with the MCNP5 code, where the bunker, the phantom and the model of the15 MV LINAC head were modeled. As the incoming beam goes into the phantom the neutron spectrum is modified and the dosimetric values are reduced.
Authors:
 [1] ;  [2]
  1. Centro Estatal de Cancerologia de Nayarit, Calzada de la Cruz 118 Sur, Tepic Nayarit, Mexico and Instituto Tecnico Superior de Radiologia, ITEC, Calle Leon 129, Tepic Nayarit (Mexico)
  2. Universidad Autonoma de Zacatecas, Unidad Academica de Estudios Nucleares, Apdo. postal 336, 98000, Zacatecas, Zac. (Mexico)
Publication Date:
OSTI Identifier:
22390508
Resource Type:
Journal Article
Resource Relation:
Journal Name: AIP Conference Proceedings; Journal Volume: 1626; Journal Issue: 1; Conference: 13. Mexican Symposium on Medical Physics, Leon, Guanajuato (Mexico), 15-16 Mar 2014; Other Information: (c) 2014 AIP Publishing LLC; Country of input: International Atomic Energy Agency (IAEA)
Country of Publication:
United States
Language:
English
Subject:
61 RADIATION PROTECTION AND DOSIMETRY; ABSORBED RADIATION DOSES; COMPUTERIZED SIMULATION; KERMA; M CODES; NEUTRON DOSIMETRY; NEUTRON SPECTRA; PHANTOMS; WATER