Title: Contamination effects on fixed-bias Langmuir probes

Journal Article · · Review of Scientific Instruments
DOI:https://doi.org/10.1063/1.4764582· OSTI ID:22093979
 [1];  [2]
  1. Institut fuer Experimentelle und Angewandte Physik, Christian-Albrechts-Universitaet zu Kiel, 24098 Kiel (Germany)
  2. Department of Physical Sciences, Embry-Riddle Aeronautical University, Daytona Beach, Florida 32114 (United States)

Langmuir probes are standard instruments for plasma density measurements on many sounding rockets. These probes can be operated in swept-bias as well as in fixed-bias modes. In swept-bias Langmuir probes, contamination effects are frequently visible as a hysteresis between consecutive up and down voltage ramps. This hysteresis, if not corrected, leads to poorly determined plasma densities and temperatures. With a properly chosen sweep function, the contamination parameters can be determined from the measurements and correct plasma parameters can then be determined. In this paper, we study the contamination effects on fixed-bias Langmuir probes, where no hysteresis type effect is seen in the data. Even though the contamination is not evident from the measurements, it does affect the plasma density fluctuation spectrum as measured by the fixed-bias Langmuir probe. We model the contamination as a simple resistor-capacitor circuit between the probe surface and the plasma. We find that measurements of small scale plasma fluctuations (meter to sub-meter scale) along a rocket trajectory are not affected, but the measured amplitude of large scale plasma density variation (tens of meters or larger) is attenuated. From the model calculations, we determine amplitude and cross-over frequency of the contamination effect on fixed-bias probes for different contamination parameters. The model results also show that a fixed bias probe operating in the ion-saturation region is affected less by contamination as compared to a fixed bias probe operating in the electron saturation region.

OSTI ID:
22093979
Journal Information:
Review of Scientific Instruments, Vol. 83, Issue 11; Other Information: (c) 2012 American Institute of Physics; Country of input: International Atomic Energy Agency (IAEA); ISSN 0034-6748
Country of Publication:
United States
Language:
English

Similar Records

Spatiotemporal temperature fluctuation measurements by means of a fast swept Langmuir probe array
Journal Article · Tue May 15 00:00:00 EDT 2007 · Review of Scientific Instruments · OSTI ID:22093979

Revisiting plasma hysteresis with an electronically compensated Langmuir probe
Journal Article · Sat Sep 15 00:00:00 EDT 2012 · Review of Scientific Instruments · OSTI ID:22093979

High-speed dual Langmuir probe
Journal Article · Thu Jul 15 00:00:00 EDT 2010 · Review of Scientific Instruments · OSTI ID:22093979