Diamagnetic flux measurement in Aditya tokamak
Journal Article
·
· Review of Scientific Instruments
- Institute for Plasma Research, Bhat, Near Indira Bridge, Gandhinagar 382428 (India)
Measurements of diamagnetic flux in Aditya tokamak for different discharge conditions are reported for the first time. The measured diamagnetic flux in a typical discharge is less than 0.6 mWb and therefore it has required careful compensation for various kinds of pick-ups. The hardware and software compensations employed in this measurement are described. We introduce compensation of a pick-up due to plasma current of less than 20 kA in short duration discharges, in which plasma pressure gradient is supposed to be negligible. The flux measurement during radio frequency heating is also presented in order to validate compensation.
- OSTI ID:
- 22062216
- Journal Information:
- Review of Scientific Instruments, Vol. 81, Issue 12; Other Information: (c) 2010 American Institute of Physics; Country of input: International Atomic Energy Agency (IAEA); ISSN 0034-6748
- Country of Publication:
- United States
- Language:
- English
Similar Records
Diamagnetic loop measurement in Korea Superconducting Tokamak Advanced Research machine
Core-ion temperature measurement of the ADITYA tokamak using passive charge exchange neutral particle energy analyzer
Diamagnetic measurements in the STOR-M tokamak by a flux loop system exterior to the vacuum vessel
Journal Article
·
Wed Jun 15 00:00:00 EDT 2011
· Review of Scientific Instruments
·
OSTI ID:22062216
Core-ion temperature measurement of the ADITYA tokamak using passive charge exchange neutral particle energy analyzer
Journal Article
·
Fri Feb 15 00:00:00 EST 2013
· Review of Scientific Instruments
·
OSTI ID:22062216
+2 more
Diamagnetic measurements in the STOR-M tokamak by a flux loop system exterior to the vacuum vessel
Journal Article
·
Fri May 15 00:00:00 EDT 2009
· Review of Scientific Instruments
·
OSTI ID:22062216
+1 more