skip to main content
OSTI.GOV title logo U.S. Department of Energy
Office of Scientific and Technical Information

Title: Collinear interferometer with variable delay for carrier-envelope offset frequency measurement

Journal Article · · Review of Scientific Instruments
DOI:https://doi.org/10.1063/1.3197404· OSTI ID:22051011
; ; ;  [1]
  1. Institute of Experimental Physics, University of Warsaw, ul. Hoza 69, 00-681 Warsaw (Poland)

We demonstrate a novel scheme for measuring the carrier-envelope offset frequency in a femtosecond optical frequency comb. Our method is based on a common-path interferometer with a calcite Babinet-Soleil compensator employed to control the delay between the two interfering beams of pulses. The large delay range (up to 8 ps) of our device is sufficient for systems that rely on spectral broadening in microstructured fibers. We show an experimental proof that the stability of a common-path arrangement is superior to that of the standard interferometers.

OSTI ID:
22051011
Journal Information:
Review of Scientific Instruments, Vol. 80, Issue 8; Other Information: (c) 2009 American Institute of Physics; Country of input: International Atomic Energy Agency (IAEA); ISSN 0034-6748
Country of Publication:
United States
Language:
English