Measurements of control rod worth by modified inverse kinetic method
Journal Article
·
· Physics of Atomic Nuclei
- Russian Research Centre Kurchatov Institute (Russian Federation)
Results of control rod worth measurements on the Astra critical assembly at the Russian Research Centre Kurchatov Institute are presented. The measurements were carried out by the modified inverse kinetics method, which is based on the use of experimental information about the variation of neutron detector readings only after introducing a reactivity perturbation. Calculated corrections are not required. The results of measurements do not depend on the neutron detector position.
- OSTI ID:
- 22029869
- Journal Information:
- Physics of Atomic Nuclei, Vol. 74, Issue 14; Other Information: Copyright (c) 2011 Pleiades Publishing, Ltd.; Country of input: International Atomic Energy Agency (IAEA); ISSN 1063-7788
- Country of Publication:
- United States
- Language:
- English
Similar Records
Reactivity Worth Measurement of Control Rods of CFBR-II with Inverse Kinetics Method
Calculating Control Rod Differential Worth Using Adjoint-Weighted Method
PERTURBATION THEORY CONTROL ROD WORTH
Journal Article
·
Sat Jul 01 00:00:00 EDT 2017
· Transactions of the American Nuclear Society
·
OSTI ID:22029869
Calculating Control Rod Differential Worth Using Adjoint-Weighted Method
Journal Article
·
Sat Jul 01 00:00:00 EDT 2017
· Transactions of the American Nuclear Society
·
OSTI ID:22029869
PERTURBATION THEORY CONTROL ROD WORTH
Technical Report
·
Sat Dec 01 00:00:00 EST 1956
·
OSTI ID:22029869