Title: Ten Years of Experience with the GORE EXCLUDER{sup Registered-Sign} Stent-Graft for the Treatment of Aortic and Iliac Aneurysms: Outcomes from a Single Center Study

Journal Article · · Cardiovascular and Interventional Radiology
; ;  [1];  [2];  [3];  [1]; ;  [2]
  1. University Hospitals Leuven, Department of Radiology (Belgium)
  2. University Hospitals Leuven, Department of Vascular Surgery (Belgium)
  3. Catholic University of Leuven, Department of Biostatistics and Statistical Bioinformatics (Belgium)

Purpose: This study was designed to assess the long-term outcome of selected patients with aortic, aortoiliac, and isolated common iliac aneurysms treated with the GORE EXCLUDER{sup Registered-Sign} stent-graft. Methods: Between December 1998 and June 2010, 121 nonconsecutive patients underwent insertion of a GORE EXCLUDER{sup Registered-Sign} stent-graft to treat an aortic (n = 80; 66%), aortoiliac (n = 25; 21%), or isolated common iliac (n = 16; 13%) aneurysm. Procedural and follow-up data were collected prospectively. Primary endpoints are overall survival, intervention-free survival, and freedom from aneurysm rupture. Secondary endpoints are device- and procedure-related complications, including all types of endoleaks or endotension, and reintervention. Results: The mean follow-up is 4.98 years (standard deviation, 3.18; median follow-up, 4.05 years). The estimated percentage overall survival (with 95% confidence interval) after respectively 5 and 10 years of follow-up is 74.5% (65.8; 81.3) and 57.8% (47.7; 66.7). The estimated intervention-free survival after respectively 5 and 10 years is 90% (84.3; 96.1) and 77.7% (67; 88.4). There was no aneurysm rupture during follow-up. Early postoperative complications occurred in 16 patients (13%); none were fatal. Late reinterventions were performed in 18 patients (15%). Finally, throughout the follow-up period, endoleaks were identified: type I (n = 4; 3%); type II (n = 39; 32%); type III (n = 0; 0%); endotension was seen in 11 patients (9%). Conclusions: Aneurysm exclusion with use of the GORE EXCLUDER{sup Registered-Sign} stent-graft is durable through a mean follow-up of nearly 5 years. There was no postprocedural aneurysm rupture. Complications occurred throughout the follow-up period, requiring continued clinical and radiological surveillance.

OSTI ID:
21608521
Journal Information:
Cardiovascular and Interventional Radiology, Vol. 35, Issue 3; Other Information: DOI: 10.1007/s00270-011-0235-6; Copyright (c) 2012 Springer Science+Business Media, LLC and the Cardiovascular and Interventional Radiological Society of Europe (CIRSE); Country of input: International Atomic Energy Agency (IAEA); ISSN 0174-1551
Country of Publication:
United States
Language:
English

Similar Records

Long-Term Follow-Up After Endovascular Treatment of Acute Aortic Emergencies
Journal Article · Tue Jan 15 00:00:00 EST 2008 · Cardiovascular and Interventional Radiology · OSTI ID:21608521

Hybrid Repair of Complex Thoracic Aortic Arch Pathology: Long-Term Outcomes of Extra-anatomic Bypass Grafting of the Supra-aortic Trunk
Journal Article · Fri Feb 15 00:00:00 EST 2013 · Cardiovascular and Interventional Radiology · OSTI ID:21608521

Ten-Year Follow-Up of Endovascular Aneurysm Treatment with Talent Stent-Grafts
Journal Article · Tue Sep 15 00:00:00 EDT 2009 · Cardiovascular and Interventional Radiology · OSTI ID:21608521