Restenosis of the CYPHER-Select, TAXUS-Express, and Polyzene-F Nanocoated Cobalt-Chromium Stents in the Minipig Coronary Artery Model
- University Heidelberg, Department of Radiology (Germany)
- University Heidelberg, Department of Pathology (Germany)
PurposeTo date no direct experimental comparison between the CYPHER-Select and TAXUS-Express stents is available. Therefore, we investigated late in-stent stenosis, thrombogenicity, and inflammation, comparing the CYPHER-Select, TAXUS-Express, and custom-made cobalt chromium Polyzene-F nanocoated stents (CCPS) in the minipig coronary artery model.MethodsThe three stent types were implanted in the right coronary artery of 30 minipigs. The primary endpoint was in-stent stenosis assessed by quantitative angiography and microscopy. Secondary endpoints were inflammation and thrombogenicity evaluated by scores for inflammation and immunoreactivity (C-reactive protein and transforming growth factor beta). Follow-up was at 4 and 12 weeks.ResultsStent placement was successful in all animals; no thrombus deposition occurred. Quantitative angiography did not depict statistically significant differences between the three stent types after 4 and 12 weeks. Quantitative microscopy at 4 weeks showed a statistically significant thicker neointima (p = 0.0431) for the CYPHER (105.034 {+-} 62.52 {mu}m) versus the TAXUS (74.864 {+-} 66.03 {mu}m) and versus the CCPS (63.542 {+-} 39.57 {mu}m). At 12 weeks there were no statistically significant differences. Inflammation scores at 4 weeks were significantly lower for the CCPS and CYPHER compared with the TAXUS stent (p = 0.0431). After 12 weeks statistical significance was only found for the CYPHER versus the TAXUS stent (p = 0.0431). The semiquantitative immunoreactivity scores for C-reactive protein and transforming growth factor beta showed no statistically significant differences between the three stent types after 4 and 12 weeks.ConclusionsThe CCPS provided effective control of late in-stent stenosis and thrombogenicity in this porcine model compared with the two drug-eluting stents. Its low inflammation score underscores its noninflammatory potential and might explain its equivalence to the two DES.
- OSTI ID:
- 21450351
- Journal Information:
- Cardiovascular and Interventional Radiology, Vol. 31, Issue 5; Other Information: DOI: 10.1007/s00270-007-9243-y; Copyright (c) 2008 Springer Science+Business Media, LLC; ISSN 0174-1551
- Country of Publication:
- United States
- Language:
- English
Similar Records
Reduction of Late In-Stent Stenosis in a Porcine Coronary Artery Model by Cobalt Chromium Stents with a Nanocoat of Polyphosphazene (Polyzene-F)
Biocompatibility and Recanalization Characteristics of Hydrogel Microspheres with Polyzene-F as Polymer Coating
Related Subjects
BIOMEDICAL RADIOGRAPHY
CHROMIUM
COBALT
CORONARIES
GROWTH FACTORS
IMMUNITY
INFLAMMATION
MICROSCOPY
ARTERIES
BLOOD VESSELS
BODY
CARDIOVASCULAR SYSTEM
DIAGNOSTIC TECHNIQUES
ELEMENTS
MEDICINE
METALS
MITOGENS
NUCLEAR MEDICINE
ORGANIC COMPOUNDS
ORGANS
PATHOLOGICAL CHANGES
PROTEINS
RADIOLOGY
SYMPTOMS
TRANSITION ELEMENTS