Modeling Plan-Related Clinical Complications Using Machine Learning Tools in a Multiplan IMRT Framework
- Industrial and Systems Engineering Department, University of Wisconsin, Madison, WI (United States)
- Computer Sciences Department, University of Wisconsin, Madison, WI (United States)
Purpose: To predict organ-at-risk (OAR) complications as a function of dose-volume (DV) constraint settings without explicit plan computation in a multiplan intensity-modulated radiotherapy (IMRT) framework. Methods and Materials: Several plans were generated by varying the DV constraints (input features) on the OARs (multiplan framework), and the DV levels achieved by the OARs in the plans (plan properties) were modeled as a function of the imposed DV constraint settings. OAR complications were then predicted for each of the plans by using the imposed DV constraints alone (features) or in combination with modeled DV levels (plan properties) as input to machine learning (ML) algorithms. These ML approaches were used to model two OAR complications after head-and-neck and prostate IMRT: xerostomia, and Grade 2 rectal bleeding. Two-fold cross-validation was used for model verification and mean errors are reported. Results: Errors for modeling the achieved DV values as a function of constraint settings were 0-6%. In the head-and-neck case, the mean absolute prediction error of the saliva flow rate normalized to the pretreatment saliva flow rate was 0.42% with a 95% confidence interval of (0.41-0.43%). In the prostate case, an average prediction accuracy of 97.04% with a 95% confidence interval of (96.67-97.41%) was achieved for Grade 2 rectal bleeding complications. Conclusions: ML can be used for predicting OAR complications during treatment planning allowing for alternative DV constraint settings to be assessed within the planning framework.
- OSTI ID:
- 21281984
- Journal Information:
- International Journal of Radiation Oncology, Biology and Physics, Vol. 74, Issue 5; Other Information: DOI: 10.1016/j.ijrobp.2009.02.065; PII: S0360-3016(09)00369-1; Copyright (c) 2009 Elsevier Science B.V., Amsterdam, The Netherlands, All rights reserved; Country of input: International Atomic Energy Agency (IAEA); ISSN 0360-3016
- Country of Publication:
- United States
- Language:
- English
Similar Records
A role for biological optimization within the current treatment planning paradigm
Using individual patient anatomy to predict protocol compliance for prostate intensity-modulated radiotherapy