skip to main content
OSTI.GOV title logo U.S. Department of Energy
Office of Scientific and Technical Information

Title: Digital I/Q demodulation for KSTAR ion cyclotron range of frequency system

Journal Article · · Review of Scientific Instruments
DOI:https://doi.org/10.1063/1.3077281· OSTI ID:21266753
; ;  [1]
  1. Korea Atomic Energy Research Institute, Daejeon 305-353 (Korea, Republic of)

An ion cyclotron range of frequency system requires rf diagnostics for a rf-plasma coupling or for maintaining a correct operation. A detector based on a digital I/Q demodulation technique collects the rf amplitude and phase at the same time without errors from the I/Q imbalance inherent in an analog counterpart. The theory of such a detector was studied and implemented for the first campaign of the KSTAR tokamak. Experimental results of the rf and other diagnostics are presented and discussed.

OSTI ID:
21266753
Journal Information:
Review of Scientific Instruments, Vol. 80, Issue 2; Other Information: DOI: 10.1063/1.3077281; (c) 2009 American Institute of Physics; Country of input: International Atomic Energy Agency (IAEA); ISSN 0034-6748
Country of Publication:
United States
Language:
English

Similar Records

Control and Data Acquisition System for KSTAR ICRF
Journal Article · Thu Nov 26 00:00:00 EST 2009 · AIP Conference Proceedings · OSTI ID:21266753

An initial measurement of a fast neutral spectrum for ion cyclotron range of frequency heated plasma using two-channel compact neutral particle analyzers in KSTAR
Journal Article · Fri Nov 15 00:00:00 EST 2013 · Review of Scientific Instruments · OSTI ID:21266753

Electron cyclotron emission diagnostics on KSTAR tokamak