Title: Overview of equilibrium reconstruction on DIII-D using new measurements from an expanded motional Stark effect diagnostic

Journal Article · · Review of Scientific Instruments
DOI:https://doi.org/10.1063/1.2955711· OSTI ID:21266672
; ; ;  [1];  [2]
  1. Lawrence Livermore National Laboratory, 7000 East Ave., Livermore, California 94550 (United States)
  2. General Atomics, P.O. Box 85608, San Diego, California 92186-5608 (United States)

Motional Stark effect (MSE) measurements constrain equilibrium reconstruction of DIII-D tokamak plasmas using the equilibrium code EFIT. In 2007, two new MSE arrays were brought online, bringing the system to three core arrays, two edge arrays, and 64 total channels. We present the first EFIT reconstructions using this expanded system. Safety factor and E{sub R} profiles produced by fitting to data from the two new arrays and one of the other three agree well with independent measurements. Comparison of the data from the three arrays that view the core shows that one of the older arrays is inconsistent with the other two unless the measured calibration factors for this array are adjusted. The required adjustments depend on the toroidal field and plasma current direction, and on still other uncertain factors that change as the plasma evolves. We discuss possible sources of calibration error for this array.

OSTI ID:
21266672
Journal Information:
Review of Scientific Instruments, Vol. 79, Issue 10; Conference: HTPD08: 17. topical conference on high-temperature plasma diagnostics, Albuquerque, NM (United States), 11-15 May 2008; Other Information: DOI: 10.1063/1.2955711; (c) 2008 American Institute of Physics; Country of input: International Atomic Energy Agency (IAEA); ISSN 0034-6748
Country of Publication:
United States
Language:
English