skip to main content
OSTI.GOV title logo U.S. Department of Energy
Office of Scientific and Technical Information

Title: Diamagnetic loop for the first plasma in the KSTAR machine

Journal Article · · Review of Scientific Instruments
DOI:https://doi.org/10.1063/1.2956963· OSTI ID:21266607
; ;  [1]
  1. National Fusion Research Institute, Gwahangno 113, Yuseong-Gu, Daejeon 305-333 (Korea, Republic of)

The diamagnetic loop (DL) is installed for the plasma diamagnetic measurement at the first plasma in the Korea superconducting tokamak advanced research (KSTAR) machine. Experimental results from the position measurement of the DL inside the KSTAR vacuum vessel and the vacuum flux measurement by using the DL for the evaluation of the geometrical data and the balance coefficient of the DL for the compensation of the vacuum flux in the diamagnetic measurement are described. In addition, a preliminary work of an instrument for a hardware compensation of the vacuum flux is presented.

OSTI ID:
21266607
Journal Information:
Review of Scientific Instruments, Vol. 79, Issue 10; Conference: HTPD08: 17. topical conference on high-temperature plasma diagnostics, Albuquerque, NM (United States), 11-15 May 2008; Other Information: DOI: 10.1063/1.2956963; (c) 2008 American Institute of Physics; Country of input: International Atomic Energy Agency (IAEA); ISSN 0034-6748
Country of Publication:
United States
Language:
English