skip to main content
OSTI.GOV title logo U.S. Department of Energy
Office of Scientific and Technical Information

Title: Upgrade of the JET Gamma-Ray Cameras

Journal Article · · AIP Conference Proceedings
DOI:https://doi.org/10.1063/1.2905085· OSTI ID:21136786
; ; ; ;  [1]; ; ; ; ;  [2]; ; ; ; ; ; ; ; ; ;  [3]
  1. Association EURATOM-MEdC, National Institute for Cryogenics and Isotopic Technologies, Rm. Valcea (Romania)
  2. Association EURATOM-MEdC, National Institute for Laser, Plasma and Radiation Physics, Bucharest (Romania)
  3. Association EURATOM-UKAEA/JOC, Culham Science Centre, Abingdon (United Kingdom)

The JET gamma-ray camera diagnostics have already provided valuable information on the gamma-ray imaging of fast ion in JET plasmas /1,2/. The applicability of gamma-ray imaging to high performance deuterium and deuterium-tritium JET discharges is strongly dependent on the fulfilment of rather strict requirements for the characterisation of the neutron and gamma-ray radiation fields. These requirements have to be satisfied within very stringent boundary conditions for the design, such as the requirement of minimum impact on the co-existing neutron camera diagnostics. The JET Gamma-Ray Cameras (GRC) upgrade project deals with these issues with particular emphasis on the design of appropriate neutron/gamma-ray filters ('neutron attenuators'). Several design versions have been developed and evaluated for the JET GRC neutron attenuators at the conceptual design level. The main design parameter was the neutron attenuation factor. The two design solutions, that have been finally chosen and developed at the level of scheme design, consist of: a) one quasi-crescent shaped neutron attenuator (for the horizontal camera) and b) two quasi-trapezoid shaped neutron attenuators (for the vertical one). The second design solution has different attenuation lengths: a short version, to be used together with the horizontal attenuator for deuterium discharges, and a long version to be used for high performance deuterium and DT discharges. Various neutron-attenuating materials have been considered (lithium hydride with natural isotopic composition and {sup 6}Li enriched, light and heavy water, polyethylene). Pure light water was finally chosen as the attenuating material for the JET gamma-ray cameras. The neutron attenuators will be steered in and out of the detector line-of-sight by means of an electro-pneumatic steering and control system. The MCNP code was used for neutron and gamma ray transport in order to evaluate the effect of the neutron attenuators on the neutron field of the JET GRC. The modelling was dedicated to the estimation of neutron and (plasma-emitted) gamma-ray attenuation, neutron-induced gamma-ray background and the neutron in-scattering impact on the neutron detectors due to the attenuator in the parking location. A numerical study of the gamma-ray detector (CsI(Tl)) was done by means of the IST Monte Carlo code. It provided preliminary results on the detector efficiency and response function.

OSTI ID:
21136786
Journal Information:
AIP Conference Proceedings, Vol. 988, Issue 1; Conference: International conference on burning plasma diagnostics, Varenna (Italy), 24-28 Sep 2007; Other Information: DOI: 10.1063/1.2905085; (c) 2008 American Institute of Physics; Country of input: International Atomic Energy Agency (IAEA). JET EFDA Contributors; ISSN 0094-243X
Country of Publication:
United States
Language:
English