skip to main content
OSTI.GOV title logo U.S. Department of Energy
Office of Scientific and Technical Information

Title: Using coherent population trapping in test atoms for magnetic field measurements in toroidal plasmas

Journal Article · · Physics of Plasmas
DOI:https://doi.org/10.1063/1.2771521· OSTI ID:21069852
; ; ; ;  [1]
  1. Institute of Applied Physics, Russian Academy of Sciences, Nizhny Novgorod (Russian Federation)

A way to measure the profile of the safety factor in toroidal controlled-fusion setups has been developed. The method is based on measuring the ratio of the poloidal magnetic field and the toroidal one locally, based on a modification of the optical resonance-fluorescence signal. The effect of partial suppression of resonance fluorescence is used, which depends on the orientation of the magnetic field relative to the laser beam, and takes place in case of coherent population trapping in test atoms with the Zeeman split-level structure, as affected by double-frequency laser radiation.

OSTI ID:
21069852
Journal Information:
Physics of Plasmas, Vol. 14, Issue 9; Other Information: DOI: 10.1063/1.2771521; (c) 2007 American Institute of Physics; Country of input: International Atomic Energy Agency (IAEA); ISSN 1070-664X
Country of Publication:
United States
Language:
English