skip to main content
OSTI.GOV title logo U.S. Department of Energy
Office of Scientific and Technical Information

Title: Sonic Infrared (IR) Imaging and Fluorescent Penetrant Inspection Probability of Detection (POD) Comparison

Journal Article · · AIP Conference Proceedings
DOI:https://doi.org/10.1063/1.2718008· OSTI ID:21054972
; ; ;  [1]
  1. Sandia National Laboratories, Airworthiness Assurance, Albuquerque, MM 87106-0615 (United States)

Sandia National Laboratories Airworthiness Assurance Nondestructive Inspection Validation Center (AANC) implemented two crack probability of detection (POD) experiments to compare in a quantitative manner the ability of Sonic Infrared (IR) Imaging and fluorescent penetrant inspection (FPI) to reliably detect cracks. Blind Sonic IR and FPI inspections were performed on titanium and Inconel registered specimens having statistically relevant flaw profiles. Inspector hit/miss data was collected and POD curves for each technique were generated and compared. In addition, the crack lengths for a number of titanium and Inconel registered reference standards were measured before and after repeated Sonic IR inspections to determine if crack growth occurred.

OSTI ID:
21054972
Journal Information:
AIP Conference Proceedings, Vol. 894, Issue 1; Conference: Conference on review of progress in quantitative nondestructive evaluation, Portland, OR (United States), 30 Jul - 4 Aug 2006; Other Information: DOI: 10.1063/1.2718008; (c) 2007 American Institute of Physics; Country of input: International Atomic Energy Agency (IAEA); ISSN 0094-243X
Country of Publication:
United States
Language:
English