Title: Thermographic calorimetry of the neutral beam injectors heating beams at TJ-II

Journal Article · · Review of Scientific Instruments
DOI:https://doi.org/10.1063/1.2220067· OSTI ID:20861226
; ; ; ; ; ; ; ; ; ; ; ; ; ;  [1]
  1. Laboratorio Nacional de Fusion/Asociacion EURATOM-CIEMAT, Avenida Complutense 22, 28040 Madrid (Spain)

A new beam diagnostic based on infrared thermography has been developed for the neutral beam injectors of the stellarator TJ-II. A highly anisotropic movable target intercepts the beam at its entrance into the stellarator. The thermal print of the beam is captured with a high resolution infrared camera. The infrared images of the target can be translated, with the appropriate analysis, into power density patterns of the beam. The system is calibrated in situ with two thermocouples adiabatically mounted in the target. The two-dimensional beam power density distribution can be accurately characterized allowing beam optimization with respect to the different parameters involved in the beam formation and transport.

OSTI ID:
20861226
Journal Information:
Review of Scientific Instruments, Vol. 77, Issue 10; Other Information: DOI: 10.1063/1.2220067; (c) 2006 American Institute of Physics; Country of input: International Atomic Energy Agency (IAEA); ISSN 0034-6748
Country of Publication:
United States
Language:
English