Gas Feeding System Supplying the U-400M Cyclotron Ion Source with Hydrogen Isotopes
Journal Article
·
· Fusion Science and Technology
- Russian Federal Nuclear Centre - All-Russia Scientific Research Institute of Experimental Physics (Russian Federation)
Automated system feeding into ion source hydrogen isotopes as molecules with preset ratio of the fluxes is described. The control system automatically maintained the working parameters and provided graphic and digital representation of the controlled processes. The radiofrequency (RF) ion source installed at the axial injection line of the cyclotron produced ion beams of HD{sup +}, HT{sup +}, DT{sup +}, D{sub 2}H{sup +}, etc. At a several months DT{sup +} beam acceleration the tritium consumption was less than 108 Bq/hr. The intensity of a 58.2 MeV triton beam (T{sup +} ions) extracted from the cyclotron chamber was about 10 nA.
- OSTI ID:
- 20854243
- Journal Information:
- Fusion Science and Technology, Vol. 48, Issue 1; Other Information: Copyright (c) 2006 American Nuclear Society (ANS), United States, All rights reserved. http://epubs.ans.org/; Country of input: International Atomic Energy Agency (IAEA); ISSN 1536-1055
- Country of Publication:
- United States
- Language:
- English
Similar Records
Automatic control system of the PIG ion source for the U-400 cyclotron
Process monitoring of tritium concentration
Process monitoring of tritium concentration
Conference
·
Mon Jan 01 00:00:00 EST 1990
· Review of Scientific Instruments; (USA)
·
OSTI ID:20854243
+4 more
Process monitoring of tritium concentration
Journal Article
·
Fri Apr 01 00:00:00 EST 1983
· J. Vac. Sci. Technol., A; (United States)
·
OSTI ID:20854243
Process monitoring of tritium concentration
Conference
·
Fri Jan 01 00:00:00 EST 1982
·
OSTI ID:20854243