skip to main content
OSTI.GOV title logo U.S. Department of Energy
Office of Scientific and Technical Information

Title: Distributions of {beta}{sup +} decayed nuclei generated in the CH{sub 2} and H{sub 2}O targets by the target nuclear fragment reaction using therapeutic MONO and SOBP proton beam

Journal Article · · Medical Physics
DOI:https://doi.org/10.1118/1.1879692· OSTI ID:20634649
; ; ; ;  [1]
  1. Department of Radiology, National Cancer Center, Kashiwa, 6-5-1 Kashiwano-ha, Kashiwa-shi, Chiba 277-8577 (Japan)

In proton radiotherapy, the irradiation dose can be concentrated on a tumor. To use this radiotherapy efficiently in the clinical field, it is necessary to evaluate the proton-irradiated area and condition. The proton-irradiated area can be confirmed by coincidence detection of pair annihilation gamma rays from {beta}{sup +} decayed nuclei generated by target nuclear fragment reaction of irradiated proton nuclei and nuclei in the irradiation target. In this study, we performed experiments of proton irradiation to a polyethylene (PE:CH{sub 2}) target containing {sup 12}C nuclei, which is a major component of the human body, and a gelatinous water (H{sub 2}O) target containing {sup 16}O nuclei at different proton irradiation energy levels under different beam conditions of mono-energetic Bragg peak and spread-out Bragg peak. The distribution of the activity in the target after proton irradiation was measured by a positron emission tomography (PET) apparatus, and compared with the calculated distribution. The temporal dependence of the activity distribution during the period between the completion of proton irradiation and the start of measurement by the PET apparatus was examined. The activity by clinical proton irradiation was 3 kB/cc in the PE target and 13 kB/cc in the water target, indicating that the intensity was sufficient for the evaluation of the distribution. The range of the activity distribution against the physical range was short (several millimeter water equivalent length), indicating the presence of target dependence. The range difference in the water target was slightly large with time dependence until the start of measurement. The difference of the lateral widths with full width half at maximum in the distributions of the measured irradiated dose and activity was within 1 mm.

OSTI ID:
20634649
Journal Information:
Medical Physics, Vol. 32, Issue 4; Other Information: DOI: 10.1118/1.1879692; (c) 2005 American Association of Physicists in Medicine; Country of input: International Atomic Energy Agency (IAEA); ISSN 0094-2405
Country of Publication:
United States
Language:
English