Title: A sensitive, selective, and portable detector for contraband: The compact integrated narcotics detection instrument

Journal Article · · Transactions of the American Nuclear Society
OSTI ID:20093649

A Compact Integrated Narcotics Detection Instrument (CINDI) has been developed at NOVA R and D, Inc., in cooperation with the US Coast Guard. This detector utilizes neutrons emitted from {sup 252}Cf. Neutrons emitted from the front face of CINDI penetrate dense compartment barrier materials with little change in energy but are backscattered by hydrogen-rich materials such as drugs. The backscattered neutrons are detected, and the rate is displayed by a microprocessor-controller integrated into CINDI. The operator guides the detector along a suspected area and receives immediate feedback from the state-of-the-art electronics. For user safety, the device incorporates a highly sensitive detection scheme to permit the use of a very weak radioactive source, without compromising detectability. CINDI is capable of detecting narcotics effectively behind panels made of steel, wood, fiberglass, or even lead-lined materials. This makes it useful for inspecting marine vessels, ship bulkheads, automobiles, structure walls, or small sealed containers. Figure 2 shows three views of the CINDI instrument. CINDI responds strongly to hydrogen-rich materials such as narcotics. It has been tested at NOVA, the US Coast Guard, and Brewt Power Systems. The results of the tests show excellent response and specificity to narcotics. CINDI has led to a new technology that shows promise for identifying the concealed contraband. The new technique uses a fusion of two independent but complementary signals for detecting and possibly identifying concealed drugs in a variety of carriers such as vehicles, marine vessels, airplanes, containers, cargo, and luggage. The carriers will be scanned using both neutron and gamma-ray sources. The signal from both the neutron and gamma-ray backscattering and/or transmission can be used simultaneously to detect and possibly identify the contrabands it has been trained for. A system that can produce three-dimensional images for both signals may also be developed. The two images may be combined and analyzed by a fast host computer to detect concealed contraband. The two independent signatures when analyzed simultaneously may help determine the type of concealed contraband.

OSTI ID:
20093649
Journal Information:
Transactions of the American Nuclear Society, Vol. 82; Conference: 2000 Annual Meeting - American Nuclear Society, San Diego, CA (US), 06/04/2000--06/08/2000; Other Information: PBD: 2000; ISSN 0003-018X
Country of Publication:
United States
Language:
English