Title: Effects of cathodic disbonding and blistering on current demand for cathodic protection of coated steel

Journal Article · · Corrosion (Houston)
DOI:https://doi.org/10.5006/1.3287651· OSTI ID:20034196

Cathodic disbonding, blistering, and current demand for cathodic protection were measured for nine commercial coatings for submerged steel structures. The ASTM-G8 standard test and a long-term test (2 years), simulating North Sea conditions, were used. The relevance of the ASTM-G8 test as a prequalification test was evaluated by comparing cathodic disbonding in the two tests. After 800 days in the long-term test, the correlation to ASTM-G8 was good. The correlation coefficient was 0.98. The current demand for cathodic protection increased when the coatings blistered. Examination of the blisters showed that they had cracked. After 2 years of testing, the current demand only had increased for the thin coatings (< 150 {micro}m). The current demand for the thicker coatings (> 450 {micro}m) had not increased, in spite of significant cathodic disbonding for some coatings. Coating breakdown factors, defined as the ratio between current demand for cathodic protection for the coated samples and samples of bare steel, were calculated. These factors were compared with the design values for cathodic protection in Det Norske Veritas (DNV) RP B401 and NORSOK M-CR-503. For all coatings, the coating breakdown rate was lower than the design values.

Research Organization:
Norwegian Univ. of Science and Tech., Trondheim (NO)
OSTI ID:
20034196
Journal Information:
Corrosion (Houston), Vol. 56, Issue 3; Other Information: PBD: Mar 2000; ISSN 0010-9312
Country of Publication:
United States
Language:
English

Similar Records

Use of conservatism in cathodic protection design
Conference · Tue Oct 01 00:00:00 EDT 1996 · OSTI ID:20034196

Shop primer as part of the corrosion protective coating for submerged steel structures
Conference · Thu Dec 31 00:00:00 EST 1998 · OSTI ID:20034196

Cathodic protection to mitigate external corrosion of underground steel pipe beneath disbonded coating
Journal Article · Sat Oct 01 00:00:00 EDT 1994 · Corrosion (Houston); (United States) · OSTI ID:20034196