skip to main content
OSTI.GOV title logo U.S. Department of Energy
Office of Scientific and Technical Information

Title: Simulating Physiological Response with a Passive Sensor Manikin and an Adaptive Thermal Manikin to Predict Thermal Sensation and Comfort

Conference ·
DOI:https://doi.org/10.4271/2015-01-0329· OSTI ID:1390040
 [1];  [1];  [2];  [2];  [3];  [4]
  1. National Renewable Energy Laboratory (NREL), Golden, CO (United States)
  2. ThermoAnalytics Inc.
  3. Measurement Technology NW
  4. Ford Motor Company

Reliable assessment of occupant thermal comfort can be difficult to obtain within automotive environments, especially under transient and asymmetric heating and cooling scenarios. Evaluation of HVAC system performance in terms of comfort commonly requires human subject testing, which may involve multiple repetitions, as well as multiple test subjects. Instrumentation (typically comprised of an array of temperature sensors) is usually only sparsely applied across the human body, significantly reducing the spatial resolution of available test data. Further, since comfort is highly subjective in nature, a single test protocol can yield a wide variation in results which can only be overcome by increasing the number of test replications and subjects. In light of these difficulties, various types of manikins are finding use in automotive testing scenarios. These manikins can act as human surrogates from which local skin and core temperatures can be obtained, which are necessary for accurately predicting local and whole body thermal sensation and comfort using a physiology-based comfort model (e.g., the Berkeley Comfort Model). This paper evaluates two different types of manikins, i) an adaptive sweating thermal manikin, which is coupled with a human thermoregulation model, running in real-time, to obtain realistic skin temperatures; and, ii) a passive sensor manikin, which is used to measure boundary conditions as they would act on a human, from which skin and core temperatures can be predicted using a thermophysiological model. The simulated physiological responses and comfort obtained from both of these manikin-model coupling schemes are compared to those of a human subject within a vehicle cabin compartment transient heat-up scenario.

Research Organization:
National Renewable Energy Lab. (NREL), Golden, CO (United States)
Sponsoring Organization:
USDOE Office of Energy Efficiency and Renewable Energy (EERE)
DOE Contract Number:
AC36-08GO28308
OSTI ID:
1390040
Report Number(s):
NREL/CP-5400-70104
Resource Relation:
Conference: Presented at SAE 2015 World Congress & Exhibition, 21-23 May 2015, Detroit, Michigan
Country of Publication:
United States
Language:
English

Similar Records

Spot cooling. Part 1: Human responses to cooling with air jets
Conference · Sat Dec 31 00:00:00 EST 1994 · OSTI ID:1390040

Thermal Manikin Evaluation of Liquid Cooling Garments Intended for Use in Hazardous Waste Management
Conference · Wed Feb 26 00:00:00 EST 2003 · OSTI ID:1390040

Parameters of human discomfort in warm environments
Conference · Wed Jan 01 00:00:00 EST 1986 · ASHRAE Trans.; (United States) · OSTI ID:1390040