Building America Case Study: The Impact of Thermostat Placement in Low-Load Homes in Sunny Climates, Denver, Colorado
Modern, energy-efficient homes conforming to the Zero Energy Ready Home standard face the challenge of meeting high customer expectations for comfort. Traditional heating, ventilation, and air conditioning (HVAC) sizing and control strategies may be insufficient to adequately condition each zone due to unique load patterns in each room caused by a number of factors. These factors include solar heat gains, occupant-related gains, and gains associated with appliances and electronics. Because of shrinking shell loads, these intermittent factors are having an increasingly significant impact on the thermal load in each zone. Consequently, occupant comfort can be compromised. To evaluate the impact of climate and house geometry, as well as HVAC system and control strategies on comfort conditions, IBACOS analyzed the results of 99 TRNSYS multiple-zone simulations. The results of this analysis indicate that for simple-geometry and single-story plans, a single zone and thermostat can adequately condition the entire house. Demanding house geometry and houses with multiple stories require the consideration of multiple thermostats and multiple zones.
- Research Organization:
- National Renewable Energy Lab. (NREL), Golden, CO (United States)
- Sponsoring Organization:
- USDOE Office of Energy Efficiency and Renewable Energy (EERE), Energy Efficiency Office. Building Technologies Office
- DOE Contract Number:
- AC36-08GO28308
- OSTI ID:
- 1240612
- Report Number(s):
- NREL/FS-5500-64633; DOE/GO-102016-4713
- Country of Publication:
- United States
- Language:
- English
Similar Records
Comfort in High-Performance Homes in a Hot-Humid Climate
The Uniform Methods Project: Smart Thermostat Evaluation Protocol