Heterogeneity of hydraulic properties in aquifers may lead to contaminants residing in lower-permeability zones where it is difficult to deliver remediation amendments using conventional injection processes. The focus of this effort is to examine use of a shear-thinning fluid (STF) to improve the uniformity of remedial amendment distribution within a heterogeneous aquifer. Previous studies have demonstrated the significant potential of STFs for improving remedial amendment delivery in heterogeneous aquifers, but quantitative evaluation of these improvements from field applications are lacking. A field-scale test was conducted that compares data from successive injection of a tracer in water followed by injection of a tracer in a STF to evaluate the impact of the STF on tracer distribution uniformity in the presence of permeability contrasts within the targeted injection zone. Data from tracer breakthrough at multiple depth-discrete monitoring intervals and electrical resistivity tomography showed that inclusion of STF in the injection solution slowed movement in high-permeability pathways, improved delivery of amendment to low-permeability materials, and resulted in better uniformity in injected fluid distribution within the targeted treatment zone.

Research Organization:
Pacific Northwest National Lab. (PNNL), Richland, WA (United States)
Sponsoring Organization:
USDOE
DOE Contract Number:
AC05-76RL01830
OSTI ID:
1225151
Report Number(s):
PNNL-SA-101736; 400403209
Journal Information:
Ground Water Monitoring and Remediation, Vol. 35, Issue 3; ISSN 1069-3629
Country of Publication:
United States
Language:
English

Similar Records

Field Test of Enhanced Remedial Amendment Delivery Using a Shear-Thinning Fluid
Journal Article · Mon Jun 01 00:00:00 EDT 2015 · Ground Water Monitoring and Remediation · OSTI ID:1225151

Enhanced Remedial Amendment Delivery to Subsurface Using Shear Thinning Fluid and Aqueous Foam
Journal Article · Sat Apr 23 00:00:00 EDT 2011 · Journal of Hazardous Materials, 191(1-3):249-257 · OSTI ID:1225151

Remedial Amendment Delivery near the Water Table Using Shear Thinning Fluids: Experiments and Numerical Simulations
Journal Article · Tue Aug 19 00:00:00 EDT 2014 · Environmental Processes, 1(4):331-351 · OSTI ID:1225151