Title: Measure Guideline: Deep Energy Enclosure Retrofit for Zero Energy Ready House Flat Roofs

This Measure Guideline provides design and construction information for a deep energy enclosure retrofit (DEER) solution of a flat roof assembly. It describes the strategies and procedures for an exterior retrofit of a flat, wood-framed roof with brick masonry exterior walls, using exterior and interior (framing cavity) insulation. The approach supported in this guide could also be adapted for use with flat, wood-framed roofs with wood-framed exterior walls.
Authors:
 [1] ;  [1]
  1. Building Science Corporation, Westford, MA (United States)
Publication Date:
OSTI Identifier:
1220467
Report Number(s):
DOE/GO--102015-4632
7080
DOE Contract Number:
AC36-08GO28308
Resource Type:
Technical Report
Research Org:
Building Science Corporation, Westford, MA (United States)
Sponsoring Org:
USDOE Office of Energy Efficiency and Renewable Energy (EERE), Building Technologies Office (EE-5B)
Country of Publication:
United States
Language:
English
Subject:
residential; Residential Buildings; BSC; Building America; Deep Energy Retrofit; Deep Energy Enclosure Retrofit; Enclosure Retrofit; retrofit; Flat Roof