Cross-polarization confocal imaging of subsurface flaws in silicon nitride.
- Nuclear Engineering Division
A cross-polarization confocal microscopy (CPCM) method was developed to image subsurface flaws in optically translucent silicon nitride (Si{sub 3}N{sub 4}) ceramics. Unlike conventional confocal microscopy, which measures reflected light so is applicable only to transparent and semi-transparent materials, CPCM detects scattered light from subsurface while filtering out the reflected light from ceramic surface. For subsurface imaging, the refractive-index mismatch between imaging (air) and imaged (ceramic) medium may cause image distortion and reduce resolution in the depth direction. This effect, characterized by an axial scaling factor (ASF), was analyzed and experimentally determined for glass and Si{sub 3}N{sub 4} materials. The experimental CPCM system was used to image Hertzian C-cracks generated by various indentation loads in the subsurface of a Si{sub 3}N{sub 4} specimen. It was demonstrated that CPCM may provide detailed information of subsurface cracks, such as crack angle and path, and subsurface microstructural variations.
- Research Organization:
- Argonne National Lab. (ANL), Argonne, IL (United States)
- Sponsoring Organization:
- EE
- DOE Contract Number:
- DE-AC02-06CH11357
- OSTI ID:
- 1023147
- Report Number(s):
- ANL/NE/JA-64657; TRN: US201118%%455
- Journal Information:
- Int. J. Appl. Ceram. Technol., Vol. 8, Issue 2 ; Mar. 2011
- Country of Publication:
- United States
- Language:
- ENGLISH
Similar Records
Real-time visualization of impact damage in monolithic silicon carbide and fibrous silicon carbide ceramic composite
Debonding of interfaces between beta-silicon nitride whiskers and Si-Al-Y oxynitride glasses