This document compiles and summarizes available, relevant information pertaining to Hanford Site waste tanks designated as Flammable Gas Watch List (FGWL) tanks. There are four primary objectives of this document. First, it provides summary data, including surface level readings, chemical composition, and temperature readings for each FGWL tank. This document also is intended to be used as a source of information on FGWL tanks references. More than 400 documents were used to compile the information presented in this report, and the Endnotes at the conclusion of each section; Section 5.0, {open_quotes}References;{close_quotes} and Section 6.0, {open_quotes}Sources of Information{close_quotes} are all included to direct the reader to further, more detailed sources of information that pertain to specific FGWL tanks or information. The third objective of this document is to present the specific fill history of each FGWL double-shell tank (DST), including data obtained from detailed Evaporator 242-A documents. Finally, this document includes an assessment of the total organic carbon (TOC) content of each DST.

Research Organization:
Westinghouse Hanford Co., Richland, WA (United States)
Sponsoring Organization:
USDOE, Washington, DC (United States)
DOE Contract Number:
AC06-87RL10930
OSTI ID:
10173717
Report Number(s):
WHC-EP-0711; ON: DE94016479; TRN: 94:007709
Resource Relation:
Other Information: PBD: Jan 1994
Country of Publication:
United States
Language:
English