Multi-Element Germanium Detectors with Integrated Readouts
Abstract
We have developed a series of monolithic multi-element germanium detectors coupled with custom developed CMOS application specific integrated circuit (ASIC) for readout. Several strip detectors with element counts ranging from 64 to 384 were developed and are currently used at the National Synchrotron Light Source II in Brookhaven National Laboratory and the Advanced Photon Source in Argonne National Laboratory. The detectors are photon counting and are used at high-energy diffraction and energy dispersive diffraction beamlines.
- Authors:
-
- Brookhaven National Lab. (BNL), Upton, NY (United States)
- Forschungzentrum Juelich GmbH, Juelich (Germany)
- Northwestern Univ., Evanston, IL (United States)
- Argonne National Lab. (ANL), Argonne, IL (United States)
- Publication Date:
- Research Org.:
- Brookhaven National Lab. (BNL), Upton, NY (United States); Argonne National Lab. (ANL), Argonne, IL (United States)
- Sponsoring Org.:
- USDOE Office of Science (SC), Basic Energy Sciences (BES). Scientific User Facilities Division
- OSTI Identifier:
- 1488521
- Alternate Identifier(s):
- OSTI ID: 1493879
- Report Number(s):
- BNL-209805-2018-JAAM
Journal ID: ISSN 0894-0886
- Grant/Contract Number:
- SC0012704; AC02-06CH11357
- Resource Type:
- Accepted Manuscript
- Journal Name:
- Synchrotron Radiation News
- Additional Journal Information:
- Journal Volume: 31; Journal Issue: 6; Journal ID: ISSN 0894-0886
- Publisher:
- Taylor & Francis
- Country of Publication:
- United States
- Language:
- English
- Subject:
- 47 OTHER INSTRUMENTATION
Citation Formats
Rumaiz, A. K., Kuczewski, A. J., Zhong, Z., Mead, J., Vernon, E., Pinelli, D., Dorryhee, E., Ghose, S., Caswell, T., Siddons, D. P., Krings, T., Stock, S., Miceli, A., Almer, J., and Okasinski, J. Multi-Element Germanium Detectors with Integrated Readouts. United States: N. p., 2018.
Web. doi:10.1080/08940886.2018.1528432.
Rumaiz, A. K., Kuczewski, A. J., Zhong, Z., Mead, J., Vernon, E., Pinelli, D., Dorryhee, E., Ghose, S., Caswell, T., Siddons, D. P., Krings, T., Stock, S., Miceli, A., Almer, J., & Okasinski, J. Multi-Element Germanium Detectors with Integrated Readouts. United States. https://doi.org/10.1080/08940886.2018.1528432
Rumaiz, A. K., Kuczewski, A. J., Zhong, Z., Mead, J., Vernon, E., Pinelli, D., Dorryhee, E., Ghose, S., Caswell, T., Siddons, D. P., Krings, T., Stock, S., Miceli, A., Almer, J., and Okasinski, J. Tue .
"Multi-Element Germanium Detectors with Integrated Readouts". United States. https://doi.org/10.1080/08940886.2018.1528432. https://www.osti.gov/servlets/purl/1488521.
@article{osti_1488521,
title = {Multi-Element Germanium Detectors with Integrated Readouts},
author = {Rumaiz, A. K. and Kuczewski, A. J. and Zhong, Z. and Mead, J. and Vernon, E. and Pinelli, D. and Dorryhee, E. and Ghose, S. and Caswell, T. and Siddons, D. P. and Krings, T. and Stock, S. and Miceli, A. and Almer, J. and Okasinski, J.},
abstractNote = {We have developed a series of monolithic multi-element germanium detectors coupled with custom developed CMOS application specific integrated circuit (ASIC) for readout. Several strip detectors with element counts ranging from 64 to 384 were developed and are currently used at the National Synchrotron Light Source II in Brookhaven National Laboratory and the Advanced Photon Source in Argonne National Laboratory. The detectors are photon counting and are used at high-energy diffraction and energy dispersive diffraction beamlines.},
doi = {10.1080/08940886.2018.1528432},
journal = {Synchrotron Radiation News},
number = 6,
volume = 31,
place = {United States},
year = {Tue Nov 13 00:00:00 EST 2018},
month = {Tue Nov 13 00:00:00 EST 2018}
}
Free Publicly Available Full Text
Publisher's Version of Record
Other availability
Save to My Library
You must Sign In or Create an Account in order to save documents to your library.
Works referenced in this record:
Detection Characteristics of Ge detectors with microstructured amorphous Ge contacts
journal, June 2004
- Protic, D.; Krings, T.
- IEEE Transactions on Nuclear Science, Vol. 51, Issue 3
Monolithic Multi-Element HPGe Detector Equipped With CMOS Preamplifiers: Construction and Characterization of a Demonstrator
journal, February 2015
- Tartoni, Nicola; Crook, R.; Krings, T.
- IEEE Transactions on Nuclear Science, Vol. 62, Issue 1
The PDD ASIC: Highly Efficient Energy and Timing Extraction for High-Rate Applications
conference, January 2005
- Dragone, A.; De Geronimo, G.; Fried, J.
- IEEE Nuclear Science Symposium Conference Record, 2005
Position-Sensitive Germanium Detectors
journal, February 1985
- Protic, D.; Riepe, G.
- IEEE Transactions on Nuclear Science, Vol. 32, Issue 1
A Monolithic Segmented Germanium Detector with Highly Integrated Readout
journal, December 2014
- Rumaiz, Abdul K.; Krings, T.; Siddons, D. P.
- IEEE Transactions on Nuclear Science, Vol. 61, Issue 6
Energy Dispersive X-Ray Diffraction
journal, December 2005
- Kämpfe, Bernd; Luczak, Falk; Michel, Bernd
- Particle & Particle Systems Characterization, Vol. 22, Issue 6